Data Output; Module 80 - Sorting - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Input data
Comparison state
switching output
2 (event counter)
Comparison state
toggle bit of
switching output
2 (event counter)
Input data length:
2 bytes
Output data
Tab. 8.43:
Output data for module 74
Output data
Switching output
2
Reset event
counter switching
output 2
Output data length:
2 bytes
8.13

Data output

8.13.1 Module 80 – Sorting
PROFINET-IO module identifier
Module ID: 1080
Submodule ID: 1
Description
Module to support the sorting of the output data.
Leuze electronic GmbH + Co. KG
Description
Reserved
Reserved
Indicates whether the event
counter has exceeded the set
comparative value. The bit is re-
set to the init. value by resetting
the event counter.
If "SWO switches several times"
was configured as comparison
mode, this bit is toggled each
time the event counter is ex-
ceeded. The bit is reset to the
init. value by resetting the event
counter.
Description
Reserved
Sets the state of switching out-
put 2
Sets the event counter of the ac-
tivation function (AF) for switch-
ing output 2 back to zero.
Reserved
Addr. Data type
1.0
Bit
1.1
Bit
1.2
Bit
1.3
Bit
Addr. Data type
0.0
Bit
0.1
Bit
0.5
Bit
1
Byte
BCL 248i
Value range
Initial
value
0: Not exceeded
0
1: Exceeded
0 > 1: Event
0
counter ex-
ceeded
1 > 0: Event
counter ex-
ceeded again
Value range
Initial
value
0: Switching out-
0
put 0
1: Switching out-
put 1
0 > 1: Perform
reset
1 > 0: No func-
tion
93

Advertisement

Table of Contents
loading

Table of Contents