Leuze electronic BCL 248i Operating Instructions Manual page 105

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Parameter
Slave UDP port # Port number for the UDP com-
multiScan slave
node 1
multiScan slave
node 2
multiScan slave
node 3
multiScan slave
node 4
multiScan slave
node 5
multiScan slave
node 6
multiScan slave
node 7
multiScan slave
node 8
multiScan slave
node 9
multiScan slave
node 10
Parameter length
154 bytes
Input data
Tab. 8.52:
Input data for module 92
Input data
MoE network sta-
tus
Slave status 1-8
Slave status 9-16 Status of slave participants 9-16 2
Slave status
17-23
Slave status
24-32
MoE network status
The MoE network status signals the status of the complete network. States:
• 0x00 init. state, not ready
• 0x01 network ready
The "Network ready" network status is only signaled if all configured slaves are ready, see Slave status.
Leuze electronic GmbH + Co. KG
Description
munication with the slave partici-
pants
IP address node 1
IP address node 1
IP address node 2
IP address node 3
IP address node 4
IP address node 5
IP address node 6
IP address node 7
IP address node 8
IP address node 9
Description
General status of the MoE net-
work
Status of slave participants 1-8
Status of slave participants
17-23
Status of slave participants
24-32
Addr. Data type
2
UNSIGNED16
4
IP_ADDRESS
19
IP_ADDRESS
34
IP_ADDRESS
49
IP_ADDRESS
64
IP_ADDRESS
79
IP_ADDRESS
94
IP_ADDRESS
109
IP_ADDRESS
124
IP_ADDRESS
139
IP_ADDRESS
Addr. Data type
0
UNSIGNED8
1
UNSIGNED8
UNSIGNED8
3
UNSIGNED8
4
UNSIGNED8
BCL 248i
Value range
Default
0-0xffff
10003
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
Value range
Initial
value
0-0xff
0
Bit-coded per
0
slave
Bit-coded per
0
slave
Bit-coded per
0
slave
Bit-coded per
0
slave
105