Starting up the device - Configuration
Parameter
Check digit
output 3
Code type 4
Number of
digits mode 4
Number of
digits 4.1
Number of
digits 4.2
Number of
digits 4.3
Number of
digits 4.4
Number of
digits 4.5
Reading reli-
ability 4
Check digit
method 4
Check digit
output 4
Parameter length: 33 bytes
Input data
None
Output data
None
Leuze electronic GmbH + Co. KG
Description
Turns the check digit output
on or off.
See code type 1
Specifies how the subse-
quent numbers of digits are
to be interpreted.
Decodable number of digits;
in the case of a range, this
number defines the lower
limit.
Decodable number of digits;
in the case of a range, this
number defines the upper
limit.
Decodable number of digits
in the enumeration mode.
Decodable number of digits
in the enumeration mode.
Decodable number of digits
in the enumeration mode.
Min. reading reliability to be
achieved in order to output a
read code.
Used check digit procedure
Turns the check digit output
on or off.
Address
Data type
24.7
Bit
25.0 ... 2
BitArea
5.5
26.6
Bit
26.0 ... 2
UNSIGNED8 0 ... 63
6.5
27
UNSIGNED8 0 ... 63
28
UNSIGNED8 0 ... 63
29
UNSIGNED8 0 ... 63
30
UNSIGNED8 0 ... 63
31
UNSIGNED8 1 ... 100
32.0 ... 3
BitArea
2.6
32.7
Bit
BCL 248i
Value range
Default
Check digit output
0
0: Standard
1: Not standard
See code type 1
0
0: Enumeration
0
1 : Range
0
0
0
0
0
4
0: Standard check
0
digit evaluation
1: No check digit ver-
ification
2: MOD10 Weight 3
3: MOD10 Weight2
4: MOD10 Weight
4...9
5: MOD11 Cont
6: MOD43
7: MOD16
Check digit output
0
0: Standard
1: Not standard
51