Module 61 - Laser Control; Module 63 - Alignment - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
8.11.2 Module 61 – Laser control
PROFINET-IO module identifier
Module ID: 1061
Submodule ID: 1
Description
The module defines the switch-on and switch-off position of the laser.
Parameter
Tab. 8.35:
Parameters for module 61
Parameter
Laser start posi-
tion
Laser stop posi-
tion
Parameter length
4 bytes
Input data
None
Output data
None
8.11.3 Module 63 – Alignment
PROFINET-IO module identifier
Module ID: 1063
Submodule ID: 1
Description
The module defines input and output data for the alignment mode of the BCL 248i. The alignment mode is
used for easy alignment of the BCL 248i with the bar code. Using the transmitted decoding quality as a per-
centage, the optimum alignment can be easily selected. This module should not be used in connection with
module 81 (AutoReflAct) as this may cause malfunctions.
Parameter
None
Input data
Tab. 8.36:
Input data for module 63
Input data
Decoding qual-
ity
Leuze electronic GmbH + Co. KG
Description
This parameter defines the
switch-on position of the laser
in 1/10° increments within the
visible range of the laser. The
center of the reading field cor-
responds to the 0° position.
This parameter defines the
switch-off position of the laser
in 1/10° increments within the
visible range of the laser.
Description
Transmits the current decoding quality
of the bar code located in the scan-
ning beam.
Addr. Data type
0 ... 1 UN-
SIGNED16
2 ... 3 UN-
SIGNED16
Addr. Data type
0
Byte
BCL 248i
Value range
Default
-450 ... +450
-450
[1/10 degrees]
[1/10 de-
grees]
-450 ... +450
+450 [1/10
[1/10 degrees]
degrees]
Value range
Initial
value
0 ... 100%
0 %
85