Leuze electronic BCL 248i Operating Instructions Manual page 115

Bar code reader
Table of Contents

Advertisement

Online commands
Manual definition of the reference code
Command
Description
Parameter
Acknowledgment
Example
Leuze electronic GmbH + Co. KG
'RS'
This command can be used to define a new reference code in the bar code reader
by means of direct input via the serial interface or the Ethernet interface. The data is
saved in the parameter set according to your input under reference code 1 through 2
and stored in the working buffer for direct further processing.
'RSyvxxzzzzzzzz'
y, v, x and z are placeholders (variables) for the actual input.
y
Def. reference code no.
'1'
(Code 1)
'2'
(Code 2)
v
Storage location for reference code:
'0'
RAM+EEPROM
'3'
RAM only
xx
Defined code type (see command 'CA')
z
Defined code information (1 ... 63 characters)
'RS=x'
x
Status
'0'
Valid 'Rx' command
'1'
Invalid command
'2'
Insufficient memory for reference code
'3'
Reference code has not been saved
'4'
Reference code invalid
Entry = 'RS130678654331'
Code 1 (1), RAM only (3), UPC (06), code information
BCL 248i