8.12.6 Module 71 – Switching output SWO2
PROFINET-IO module identifier
Module ID: 1071
Submodule ID: 1
NOTICE
Module 71 functions only as a switching output.
Parameter
Tab. 8.41:
Parameters for module 71
Parameter
Bias level
Reserved
Start-up delay
Switch-on time
Switch-on func-
tion 1
Switch-on func-
tion 2
Switch-off func-
tion 1
Switch-off func-
tion 2
Leuze electronic GmbH + Co. KG
Description
The parameter defines the bias level
of the switching output and, thus, si-
multaneously whether the output is
low-active (0) or high-active (1).
Free
With this parameter, the output pulse
may be delayed by a set time period
in ms
The parameter defines the switch-on
time period for the switching output
in ms. If the value is 0, the signal is
static.
This parameter specifies an event
which can set the switching output.
This parameter specifies an event
which can set the switching output.
Switch-on function 1 and switch-on
function 2 are OR linked.
This parameter specifies an event
which can reset the switching output.
This parameter specifies an event
which can reset the switching output.
Switch-off function 1 and switch-off
function 2 are OR linked.
Addr. Data type
0.1
Bit
0.2 ...
 0.7
1
UN-
SIGNED16
3
UN-
SIGNED16
5
UNSIGNED8 see chapter
6
UNSIGNED8 see chapter
7
UNSIGNED8 see chapter
8
UNSIGNED8 see chapter
BCL 248i
Value range
Default
0: LOW (0 V)
0
1: HIGH
(+Ub)
0 ... 65535
0 ms
ms
0 ... 1300 ms 400 ms
5
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
0
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
1
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
0
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"