Module 12 - Multi-Label - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
8.7.3
Module 12 – Multi-label
PROFINET-IO module identifier
Module ID: 1012
Submodule ID: 1
Description
The module permits the definition of multiple bar codes with a different number of digits and/or code types
in the reading gate and provides the necessary input data.
Parameter
Tab. 8.9:
Parameters for module 12
Parameter
Minimum num-
ber of bar codes
Maximum num-
ber of bar codes
Parameter length
2 bytes
Input data
Tab. 8.10:
Input data for module 12
Input data
Number of de-
coding results
Input data length
1 byte
Output data
None
This module is used to set the maximum and minimum number of bar codes which are to be decoded
within a reading gate.
If parameter "minimum number of bar codes" = 0, it is not taken into account at the decoder control. If it is
not equal to 0, this means that the bar code reader expects a number of labels within the set range.
If the number of decoded bar codes is within the set limits, no additional "No Reads" are output.
NOTICE
When using this module, the ACK mode should be activated (see chapter 8.7.1 "Module 10 –
Activations", "Mode" parameter). Otherwise there is a risk of losing decoding results if the con-
trol is not fast enough.
Leuze electronic GmbH + Co. KG
Description
Minimum number of different bar codes
scanned for per reading gate.
Maximum number of different bar codes
scanned for per reading gate. Only if this
number of bar codes has been reached,
the reading gate is terminated prema-
turely.
Description
Number of decoding results which have
not been fetched.
Addr. Data type
0
1
Addr. Data type
0
BCL 248i
Value
range
UNSIGNED8 0 ... 64
UNSIGNED8 0 ... 64
Value
range
UNSIGNED8 0 ... 256
Default
1
1
Initial
value
0
63

Advertisement

Table of Contents
loading