Module 5 - Code Type Features (Symbology) - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Parameter
Reading reli-
ability
Check digit
method
Check digit
output
Refer to the notice on the number of digits in see chapter 8.4.2 "Permanently defined parameters/device
parameters".
Parameter length
8 bytes
Input data
None
Output data
None
8.6.2
Module 5 – Code type features (symbology)
PROFINET-IO module identifier
Module ID: 1005
Submodule ID: 1
Description
The module defines extended features for various code types.
Leuze electronic GmbH + Co. KG
Description
Min. reading reliability to be
achieved in order to output a
read code.
Used check digit procedure
Turns the check digit output
on or off.
Standard means that the
check digit is transmitted ac-
cording to the applicable
standard for the selected
code type. If no check digit
transmission is intended for
the selected code type, then
"Standard" means that the
check digit is not transmitted
and "Not Standard" means
that the check digit is trans-
mitted anyway.
Rel.
Data type
addr.
6
UNSIGNED8 1 ... 100
7.0 ... 7.6 BitArea
7.7
Bit
BCL 248i
Value range
Default
4
0: Standard check
0
digit evaluation
1: No check digit ver-
ification
2: MOD10 Weight 3
3: MOD10 Weight2
4: MOD10 Weight
4...9
5: MOD11 Cont
6: MOD43
7: MOD16
Check digit output
0
0: Standard
1: Not standard
57