Fast commissioning
3.6

Starting the device

Ä Connect the +18 ... 30 V DC supply voltage (typically +24 V DC).
ð The BCL 248i starts up, the PWR, NET and LINK LEDs indicate the operating state.
Tab. 3.1:
Display of operating state
LED
PWR
NET
LINK
During the initialization phase (power on), the laser is switched on for approx. 2 seconds. A configuration
code can be read in during this time.
NOTICE
Setting the IP address to the Leuze default address
By reading in the configuration code during the initialization phase, the IP address and the sub-
net mask are set to the Leuze default.
IP address: 192.168.60.101
Subnet mask: 255.255.255.0
Operating the bar code reader
After connecting a supply voltage of +18 ... 30 V DC to the switching input, a read process is activated. In
the standard setting, all common code types for decoding are released. Only the 2/5 Interleaved code type
is limited to 10 digits of code content.
If a code is moved through the reading field, the code content is decoded and forwarded to the superior
system (PLC/PC) via PROFINET-IO.
Leuze electronic GmbH + Co. KG
Color
State
Green
Flashing
Continuous light
Briefly off - on
Green - red
Green off – briefly
red – green on
Yellow
Continuous light
Red
Flashing
Continuous light
Green
Flashing
Continuous light
Orange
Flashing
Red
Flashing
Continuous light
Green
Continuous light
Yellow
Flashing
192.168.060.101
Description
Device ok, initialization
Power On, device OK
Good read, reading successful
No Read, reading not successful
Service mode
Warning
Error, device error
Initialization
Network mode ok
Topology error
Communication error
Network error
Ethernet connected (LINK)
Data communication (ACT)