Online commands
Deactivate switching output
Command
Description
Parameter
Acknowledgment None
9.5

Online commands for the parameter set operations

Copying parameter set
Command
Description
Parameter
Acknowledgment 'PS=<aa>'
Leuze electronic GmbH + Co. KG
'OD'
Switching output 2 can be deactivated with this command. The logic state is output,
i.e., an inverted logic is taken into account (e.g., inverted logic and a state of High cor-
responds to a voltage of 0 V at the switching output).
'OD<a>'
<a> Selected switching output 2, unit (dimensionless)
'PC'
This command can only be used to copy parameter sets in their entirety. This can be
used to replicate the three parameter sets default, permanent and operating parame-
ters on the basis of one another. In addition, this command also be used to restore the
factory settings.
'PC<Source type><Target type>
<Source
Parameter data set that is to be copied, unit [dimensionless]
type>
'0'
Parameter data set in permanent memory
'2'
Default or factory parameter set
'3'
Operating parameter data set in volatile memory
<Target
Parameter set into which the data is to be copied, unit [dimensionless]
type>
'0'
Parameter data set in permanent memory
'3'
Operating parameter data set in volatile memory
Permissible combinations here include:
'03'
Copying the data set from the permanent memory to the operating pa-
rameter data set
'20'
Copying the operating parameter data set to the permanent parameter
set memory
'30'
Copying the default parameters to the permanent memory and to the
main memory
<aa>
Status acknowledgment, unit (dimensionless)
'00'
Ok
'01'
Syntax error
'02'
Impermissible command length
'03'
Reserved
'04'
Reserved
'05'
Reserved
'06'
Impermissible combination, source type - target type