Leuze electronic BCL 248i Operating Instructions Manual page 21

Bar code reader
Table of Contents

Advertisement

Device description
PWR LED
Tab. 4.1:
PWR indicators
Color
---
Green
Orange
Red
Leuze electronic GmbH + Co. KG
State
Description
OFF
Device off
No supply voltage
Flashing
Device ok
Continuous light
Device ok
Briefly off - on
Good Read
Green briefly off –
No read
briefly red – green on
Continuous light
Service mode
Flashing
Device ok, warning set
Continuous light
Device error/parameter enable
• Initialization phase
• Bar code reading not possible
• Supply voltage applied
• Self test running
• Bar code reading possible
• Self test successfully finished
• Device monitoring active
• Bar code reading successful
• Bar code reading not successful
• Bar code reading possible
• No data on the host interface
• Bar code reading possible
• Temporary operating fault
• Bar code reading not possible
BCL 248i
21