BCL300i and BCL301i Bar code Readers T E C H N I C A L D E S C R I P T I O N...
Page 2
Leuze electronic GmbH + Co. KG P.O. Box 1111, D- 73277 Owen Tel. +49(0) 7021/ 573-0, Fax +49(0)7021/ 573-199 info@leuze.de w.leuze.com Sales and Service Germany Sales Region North Sales Region South Sales Region East Phone 07021/573-306 Phone 07021/573-307 Phone 035027/629-106...
Page 4
Ultra Low Density (L) - optics: BCL 300i \ BCL 301i S/R1 L 102 (H) ...........63 5.5.11 Ultra Low Density (L) - optics: BCL 300i \ BCL 301i S/R1 L 100 (H) ...........63 5.5.12 Ultra Low Density (L) - optics: BCL 300i \ BCL 301i OL 100 (H) ..........64 300i \ BCL 301i Leuze electronic...
Page 5
HOST / BUS IN for BCL 301i....................... 93 7.4.5 BUS OUT for the BCL 301i......................94 Leuze multiNet plus ......................95 7.5.1 Wiring the multiNet plus....................... 96 7.5.2 The BCL 301i as network slave....................97 Cable lengths and shielding ................... 97 Leuze electronic 300i \ BCL 301i...
Page 6
’Online’ commands for system control ..................123 11.1.3 ’Online’ commands for configuration of switching inputs/outputs..........124 11.1.4 ’Online’ commands for the parameter set operations..............127 Diagnostics and troubleshooting..............134 12.1 General causes of errors....................134 12.2 Interface errors....................... 134 300i \ BCL 301i Leuze electronic...
Page 7
Disassembling, packing, disposing ................144 Appendix ......................145 15.1 Declaration of Conformity ..................... 145 15.2 ASCII character set ......................147 15.3 Bar code samples ......................151 15.3.1 Module 0.3 ..........................151 15.3.2 Module 0.5 ..........................152 Leuze electronic 300i \ BCL 301i...
Page 8
"High Density" reading field curve for line scanner with deflection mirror ..........57 Figure 5.13: "High Density" reading field curve for oscillating-mirror scanners............58 Figure 5.14: Lateral "High Density" reading field curve for oscillating-mirror scanners..........58 300i \ BCL 301i Leuze electronic...
Page 9
BCL 300i \ BCL 301i - Display ....................... 100 Figure 9.1: Connecting the SERVICE USB interface ....................102 Figure 9.2: The start page of the webConfig tool ..................... 104 Figure 9.3: Module overview in the webConfig tool....................105 Leuze electronic 300i \ BCL 301i...
Page 10
Declaration of conformity BCL 300i \ BCL 301i ..................145 Figure 15.2: Connection hood / connector unit declaration of conformity ..............146 Figure 15.3: Bar code sample labels (module 0.3)..................... 151 Figure 15.4: Bar code sample labels (module 0.5)..................... 152 300i \ BCL 301i Leuze electronic...
You can find the Declaration of Conformity of the devices in the appendix of the manual on page 145. The manufacturer of the product, Leuze electronic GmbH & Co KG in D-73277 Owen, possesses a certified quality assurance system in accordance with ISO 9001.
• Storage technology and materials handling, in particular for object identification on fast-moving transport systems • Pallet transport systems • Automobile sector • Omnidirectional reading 300i \ BCL 301i Leuze electronic...
CAUTION: Use of controls or adjustments or performance of procedures other than specified herein may result in hazardous light exposure. Leuze electronic 300i \ BCL 301i...
300i \ BCL 301i Line scanner and M12 MS 3xx connection hood Warning: laser aperture Name plate Figure 2.1: Attachment of the stick-on labels with warning notices at the BCL 300i \ BCL 301i 300i \ BCL 301i Leuze electronic...
• The reading distance lies in the middle area of the reading field. • The bar code labels are of good print quality and have good contrast ratios. • You do not use high-gloss labels. • There is no direct sunlight. Leuze electronic 300i \ BCL 301i...
- MS 300 hood with integrated M12 connectors Notice! The shielding connection is done via the M12 connector housing. Notice! The integrated parameter memory for the simple replacement of the BCL 300i is located in the MS 300. 300i \ BCL 301i Leuze electronic...
The shield is automatically contacted when the cable is lead into the metal screw fitting and fastened when the cord grip is closed. Then lead the individual wires into the terminals according to the diagram. Wire end sleeves are not necessary. Leuze electronic 300i \ BCL...
The left side of the housing of the MA 100 features a metal bracket for connecting functional earth FE to the installation surface (e.g. metallic equipment). The MA 100 contains a shielding terminal for the shielding connection of the KB 301-3000. 300i \ BCL 301i Leuze electronic...
During standalone operation of the BCL 300i, the host interface of the superior system is connected to HOST/BUS IN. Please make certain that the correct interface is used on the superior system. The standard setting of the BCL 300i for the host interface is RS 232. Leuze electronic 300i \ BCL 301i...
The bus is looped through the MS 301, i.e. the bus is not interrupted when the BCL 301i removed from the MS 301. The bus is terminated at BUS OUT via an external mounted terminating resistor (see chap- ter 13.5 "Accessory terminating resistor"). 300i \ BCL 301i Leuze electronic...
The shield is automatically contacted when the cable is lead into the metal screw fitting and fastened when the cord grip is closed. Then lead the individual wires into the terminals according to the diagram. Wire end sleeves are not necessary. Leuze electronic 300i \ BCL...
KB 301-3000. The bus is terminated via slide switch T in the MA 100. If the termination is activated (slide switch T in the ON position), the downstream bus is dis- connected. 300i \ BCL 301i Leuze electronic...
Page 23
MS 301 (see chapter 13.5 "Accessory terminating resistor"); in the MA 100 and the MK 301, termination is activated by a switch. The device address is set in multiNet via the slide or rotary switch provided for this in the MA 100, MK 301 or MS 301. Leuze electronic 300i \ BCL 301i...
Service mode flashes red Warning set red continuous light Error, device error BUS LED flashes green Initialization green continuous light Bus operation ok flashes red Communication error red continuous light Bus error 300i \ BCL 301i Leuze electronic...
Page 25
\ BCL 301i. Install this USB driver and please follow the instructions when doing so. Then, you can open the connection to the BCL through your Internet browser and perform the desired settings or tests. Leuze electronic 300i \ BCL...
(PLC/PC). Please check the incoming data of the bar code information there. Alternatively, you can use a switching input for read activation (switching signal of a photoelectric sensor or 24VDC switching signal). 300i \ BCL 301i Leuze electronic...
The interfaces (RS 232, RS 485 and RS 422) integrated in the various device models and the fieldbus systems (PROFIBUS DP, PROFINET-IO and Ethernet) offer optimum connec- tion to the superior host system. Leuze electronic 300i \ BCL 301i...
The proven code fragment technology (CRT) enables bar code readers of the BCL 300i series to read bar codes with a small bar height, as well as bar codes with a damaged or soiled print image. 300i \ BCL 301i Leuze electronic...
BCL 300i \ BCL 301i or external devices, such as a PLC. System, warning and error messages provide assistance in setup/troubleshooting during commissioning and read operation. Leuze electronic 300i \ BCL 301i...
(only MK 301) Mini-B type USB Connection side with service interface system plug for connection to 300i \ BCL 301i Figure 4.7: Device construction MK 300/MK 301 hood with integrated connectors 300i \ BCL 301i Leuze electronic...
KB 301/3000 cable hood device construction MA 100 terminal box Terminal compartment with address switches and termination Slotted hole on both sides for fastening (grounding shoe on the left) Cable lead-throughs Figure 4.9: MA 100 terminal box device construction Leuze electronic 300i \ BCL 301i...
• with bar codes having very short bar lengths. • when the ladder code is turned out of the vertical position (tilt angle). • when the reading distance is large. Figure 4.10: Deflection principle for the line scanner 300i \ BCL 301i Leuze electronic...
• when the bars of the bar code are printed perpendicular to the conveying direction ('picket fence arrangement'). • when reading stationary objects. • when a large reading field (reading window) has to be covered. Figure 4.11: Deflection principle for the line scanner with oscillating mirror add-on Leuze electronic 300i \ BCL 301i...
• when the bars of the bar code are perpendicular to the conveying direction ('picket fence arrangement') • with bar codes with low height displacement • with very glossy bar codes Figure 4.12: Deflection principle for the raster scanner 300i \ BCL 301i Leuze electronic...
MS 300 hood with integrated connectors, the MK 300 terminal hood or the KB 301-3000 cable hood together with the MA 100 terminal box are available. 300i KB 301-3000 MK 300 MS 300 MA 100 Figure 4.13: Standalone connectionBCL 300i Leuze electronic 300i \ BCL 301i...
In principle, networking occurs via a parallel connection of the individual RS 485 interfaces of the respective bar code scanners. Shielded, twisted pair conductors should be used for the Leuze multiNet plus. This allows a total network length of up to 1200m. 300i \ BCL 301i Leuze electronic...
Figure 4.15: Scanner arrangement with the multiScan function Notice! The multiScan function on the RS 485 interface is possible for minimum of 2 and a maximum of 32 devices! Leuze electronic 300i \ BCL 301i...
If the BCL is replaced with a new device, the new device takes on the settings of the old BCL from the hood with integrated connectors or terminal hood. This makes renewed configura- tion of the BCL unnecessary when it is replaced. 300i \ BCL 301i Leuze electronic...
The BCL 300i \ BCL 301i can compare read bar codes with one and/or both reference codes and execute user-configurable functions depending on the comparison result. Leuze electronic 300i \ BCL 301i...
Monochromatic graphical display, 128 x 32 pixel, with background lighting Keyboard (optional) 2 buttons LEDs 2 LEDs for power (PWR) and bus state (BUS), two-colored (red/green) Table 5.1: Specifications of the BCL 301i and BCL 300i line/raster scanners without heating Leuze electronic 300i \ BCL 301i...
Page 44
For UL applications, use is permitted exclusively in Class 2 circuits according to NEC (National Electric Code). The BCL 300i \ BCL 301i bar code readers are designed in accordance with safety class III for supply by PELV (protective extra-low voltage). 300i \ BCL 301i Leuze electronic...
300i \ BCL 301i should be mounted so that it is thermally isolated. Electrical connection The required core cross section of the connection cable for the voltage supply must be at least 0.75 mm². 300i \ BCL 301i Leuze electronic...
-20°C … +70°C Table 5.4: Specifications of the BCL 301i and BCL 300i line/raster scanners with heating 5.2.2 Oscillating-mirror scanner with heating Technical data same as for line scanner without heating with the following differences: Leuze electronic 300i \ BCL 301i...
Standard, M12 ready-made cable not usable (insufficient cable cross-section) Environmental data Operating temperature range -35°C … +40°C Storage temperature range -20°C … +70°C Table 5.6: Specifications of the BCL 301i and BCL 300i deflection-mirror scanners with heating 300i \ BCL 301i Leuze electronic...
To ensure protection class IP 65 is fulfilled, the screws of the connection hood are tightened with a tightening torque of 1.4Nm for connecting to the BCL. Figure 5.6: Dimensioned drawing of MS 3xx hood with integrated connectors / MK 3xx terminal hood Leuze electronic 300i \ BCL 301i...
To ensure protection class IP 65 is fulfilled, the screws of the connection hood are tightened with a tightening torque of 1.4Nm for connecting to the BCL. Figure 5.7: Dimensioned drawing of KB 301-3000 cable hood 300i \ BCL 301i Leuze electronic...
Therefore, above all, the module of a bar code is decisive for the size of the reading field. Notice! A rule of thumb: The smaller the module of the bar code is, the smaller the maximum reading distance and reading field width will be. 300i \ BCL 301i Leuze electronic...
8 scan lines which vary depending on the reading distance from the raster aperture. Distance [mm] starting at the zero position Front scanner Deflection mirror scanner Table 5.7: Raster line cover as a function of the distance Leuze electronic 300i \ BCL 301i...
Figure 5.10: Zero position of the reading distance Reading conditions for the reading field curves 2/5 Interleaved Bar code type 1:2.5 Ratio class A ANSI specification > 75% Reading rate Table 5.8: Reading conditions 300i \ BCL 301i Leuze electronic...
= 0,15 m = 0,2 -100 Reading distance [mm] Figure 5.12: "High Density" reading field curve for line scanner with deflection mirror The reading field curve applies for the reading conditions stated in table 5.8. Leuze electronic 300i \ BCL 301i...
= 0,15 m = 0,2 -100 Reading distance [mm] Figure 5.14: Lateral "High Density" reading field curve for oscillating-mirror scanners The reading field curves apply for the reading conditions stated in table 5.8. 300i \ BCL 301i Leuze electronic...
= 0,5 -100 -150 Reading distance [mm] Figure 5.16: "Medium Density" reading field curve for line scanner with deflection mirror The reading field curves apply for the reading conditions stated in table 5.8. Leuze electronic 300i \ BCL 301i...
= 0,5 -100 -150 -200 Reading distance [mm] Figure 5.20: "Low Density" reading field curve for line scanner with deflection mirror The reading field curves apply for the reading conditions stated in table 5.8. Leuze electronic 300i \ BCL 301i...
-150 -200 -250 -300 Reading distance [mm] Figure 5.24: "Ultra Low Density" reading field curve for line scanner with deflection mirror The reading field curves apply for the reading conditions stated in table 5.8. Leuze electronic 300i \ BCL 301i...
Save the original packaging for later storage or shipping. Notice! All BCL 300i \ BCL 301i are delivered with a protective cover on the connection side which must be removed before attaching a connection hood. Leuze electronic 300i \ BCL 301i...
Installation and mounting If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. Observe the applicable local regulations when disposing of the packaging materials. Mounting the BCL 300i \ BCL...
Clamp profile for fastening to round or oval pipes Ø 16 … 20mm All dimensions in mm A Rod holder, turnable 360° B Rods Ø 16 … 20mm Figure 6.3: BT 56 mounting device Leuze electronic 300i \ BCL 301i...
For further information, see the notices in chapter 6.3! Please refer to chapter 5.4 for the permissible minimum and maximum distances between the BCL 300i \ BCL 301i and the labels to be read. Leuze electronic 300i \ BCL 301i...
• The reading distance lies in the middle area of the reading field. • The bar code labels are of good print quality and have good contrast ratios. • You do not use high-gloss labels. • There is no direct sunlight. 300i \ BCL 301i Leuze electronic...
(rear housing wall). The BCL 300i \ BCL 301i with deflection mirror should be Bar code mounted parallel to the bar code. Zero position Figure 6.7: Total reflection – line scanner Leuze electronic 300i \ BCL 301i...
• Lowest possible chance of damage to the BCL 300i \ BCL 301i by mechanical collision or jammed parts. • Possible extraneous light (no direct sunlight or sunlight reflected by the bar code). 300i \ BCL 301i Leuze electronic...
α γ γ Figure 6.9: Reading angle for the line scanner α Tilt β Angle of inclination (Pitch) γ Skew γ In order to avoid total reflection, the skew should be greater than 10°. Leuze electronic 300i \ BCL 301i...
Remove all packaging remains, e.g. carton fibers or Styrofoam balls. In doing so, avoid leaving fingerprints on the front cover of the BCL 300i \ BCL 301i. Attention! Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device. 300i \ BCL 301i Leuze electronic...
Additional connection accessories can be found in chapter 13. Attention! The BCL 300i does not fulfill protection class IP 65 until the connection hood has been screwed on. Minimum tightening torque of the housing connection screws on the connection hood 1.4Nm! Leuze electronic 300i \ BCL 301i...
Location of the electrical connections Oscillating-mirror scanner Line scanner with deflection mirror Line scanner KB 301-3000 MK 300 MS 300 Cable Terminals M12 connector MA 100 Terminal box Figure 7.1: Location of the electrical connections 300i \ BCL 301i Leuze electronic...
Protection class IP 65 is not fulfilled until connectors or cable lead-throughs are screwed on and caps are installed! Attention! To ensure protection class IP 65 is fulfilled, the screws of the connection hood are tightened with a tightening torque of 1.4Nm for connecting to the BCL. Leuze electronic 300i \ BCL 301i...
The integrated parameter memory for the simple replacement of the BCL 300i is located in the MS 300. Notice! See chapter 5.3.6 "Dimensioned drawing of MS 3xx hood with integrated connectors / MK 3xx terminal hood" dimensioned drawing on page 51. 300i \ BCL 301i Leuze electronic...
Remove approx. 78mm of the connection cable sheathing. 15mm of sheath of the shielded line must be freely accessible. ≈ 15 mm ≈ 55 mm ≈ 8 mm Figure 7.4: Cable fabrication for MK 300 terminal hood Leuze electronic 300i \ BCL 301i...
Page 82
Then lead the individual wires into the terminals according to the diagram. Wire end sleeves are not necessary. Notice! See chapter 5.3.6 "Dimensioned drawing of MS 3xx hood with integrated connectors / MK 3xx terminal hood" dimensioned drawing on page 52. 300i \ BCL 301i Leuze electronic...
FE to the installation surface (e.g. metallic equipment). The MA 100 contains a shielding terminal for the shielding connection of the KB 301-3000. Notice! See chapter 5.3.8 "Dimensioned drawing of MA 100 terminal box" dimensioned drawing on page 53. Leuze electronic 300i \ BCL 301i...
During standalone operation of the BCL 300i, the host interface of the superior system is connected to HOST/BUS IN. Please make certain that the correct interface is used on the superior system. The standard setting of the BCL 300i for the host interface is RS 232. 300i \ BCL 301i Leuze electronic...
The bus is looped through the MS 301, i.e. the bus is not interrupted when the BCL 301i removed from the MS 301. The bus is terminated at BUS OUT via an external mounted terminating resistor (See chap- ter 13.5 "Accessory terminating resistor"). Leuze electronic 300i \ BCL 301i...
Mini-B USB socket (behind protective cap) Figure 7.8: 301i - MK 301 terminal hood with spring-loaded terminals Notice! The integrated parameter memory for simple exchange of the BCL 301i is located in the MK 301. 300i \ BCL 301i Leuze electronic...
Then lead the individual wires into the terminals according to the diagram. Wire end sleeves are not necessary. Notice! See chapter 5.3.6 "Dimensioned drawing of MS 3xx hood with integrated connectors / MK 3xx terminal hood" dimensioned drawing on page 52. Leuze electronic 300i \ BCL 301i...
The left side of the housing of the MA 100 features a metal bracket for connecting functional earth FE to the installation surface (e.g. metallic equipment). The MA 100 contains a shielding terminal for the shielding connection of the KB 301-3000. 300i \ BCL 301i Leuze electronic...
MS 301 (See chapter 13.5 "Accessory terminating resistor"); in the MA 100 and the MK 301, termination is activated by a switch. The device address is set in multiNet via the slide or rotary switch provided for this in the MA 100, MK 301 or MS 301. Leuze electronic 300i \ BCL 301i...
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only guaranteed when the functional earth is connected properly. All electrical disturbances (EMC couplings) are discharged via the functional earth connection. 300i \ BCL 301i Leuze electronic...
If, for example, the inverted sensor output is connected to pin 2, and pin 2 of the bar code reader is, at the same time, configured as an output (and not as an input), the switching output malfunctions. Attention! The maximum input current must not exceed 8mA! Leuze electronic 300i \ BCL 301i...
The entire connection cable must absolutely be shielded acc. to the USB specifications. Cable length must not exceed 3m. Use the Leuze-specific USB service cable (See chapter 13 "Type overview and acces- sories") for the connection and use a service PC to configure. 300i \ BCL 301i Leuze electronic...
RXD signal (RS 232) / RX- (RS 422) RXD/RX- yellow FE via FE via Functional earth (housing) thread screw fitting Spring-loaded terminals Table 7.3: Pin assignment HOST / BUS IN BCL 300i on the KB 301-3000 Leuze electronic 300i \ BCL 301i...
- Pin assignments - HOST / BUS IN as RS 422 Notice for connecting the RS 422 interface! Ensure adequate shielding. The entire connection cable must be shielded and earthed. The Rx+/Rx- and Tx+/Tx- wires must be stranded in pairs (Twisted Pair). 300i \ BCL 301i Leuze electronic...
RS 485 A - signal line RS485 A Functional earth / shield FE via FE via Functional earth (housing) thread screw fitting Spring-loaded terminals Table 7.4: Pin assignment HOST / BUS IN BCL 301i Leuze electronic 300i \ BCL 301i...
BUS OUT socket or via the activation of the termination via a slide switch in the MK 301 or the MA 100. Notice! The bus front on the bus master (MA 31 or BCL 500i) is automatically terminated. 300i \ BCL 301i Leuze electronic...
RS 232 or RS 422) to a superior PLC control or to a computer, i.e. it "collects" the scanner data in the network and transmits it to an interface on the host computer. This reduces inter- face costs (CPs) and time spent programming the software. Leuze electronic 300i \ BCL...
2 slave 3 slave n Figure 7.6: Leuze multiNet plus system topology Notice! Use the recommended connectors / sockets or the ready-made cables and terminating resistors (See chapter 13 "Type overview and accessories"). 300i \ BCL 301i Leuze electronic...
1200m first BCL to the RS 485 conductors, stranded in pairs last BCL BCL – power Not necessary supply unit Not necessary Switching input Not necessary Switching output Table 7.6: Cable lengths and shielding Leuze electronic 300i \ BCL 301i...
- initialization running green continuous light Device ok - bar code reading possible - self test successfully finished - device monitoring active green, briefly off - on Good read, successful reading - bar code(s) successfully read 300i \ BCL 301i Leuze electronic...
Page 101
Communication error - network error after initialization by the master (BCL 301i slave) red continuous light Network error - slave cannot transmit any more data to the master (BCL 301i slave). Leuze electronic 300i \ BCL 301i...
= bus address of the BCL 301i • Adjustmode = alignment mode • Version = software and hardware version After the voltage is switched off/on, reading result is always displayed. The display is controlled via the two control buttons: 300i \ BCL 301i Leuze electronic...
Page 103
• 1st line: alignment mode display function • 2nd line: decoding quality in percent, e.g. 73% Version • 1st line: version display function SW: xxxxx HW: xxx • 2nd line: software and hardware version of the device Leuze electronic 300i \ BCL 301i...
301i is connected via the PC -side USB interface by means of a standard USB cable, with 1 type A connector and 1 Mini-B type connector. Mini-B Figure 9.1: Connecting the SERVICE USB interface 300i \ BCL 301i Leuze electronic...
Upon successful installation of the USB driver, an icon with the name Leuze Web Config automatically appears on the desktop. Notice! If the installation failed, contact your network administrator: The settings of the firewall used may need to be adjusted. Leuze electronic 300i \ BCL 301i...
The individual parameters are – where useful – graphically displayed in order to better illustrate the meaning of the what are often perceived as abstract parameters. The result is an easy-to-use and practically-oriented user interface! 300i \ BCL 301i Leuze electronic...
The user interface of the webConfig tool is largely self-explanatory. 9.4.1 Module overview in the Configuration menu The adjustable parameters of the BCL 300i \ BCL 301i are clustered in modules in the Configuration menu. Figure 9.3: Module overview in the webConfig tool Leuze electronic 300i \ BCL 301i...
Page 108
During commissioning of the BCL 300i \ BCL 301i, it is recommended that the individual modules be configured in the order presented above. Further information on commissioning can be found in chapter "Commissioning and configuration" on page 107. 300i \ BCL 301i Leuze electronic...
USB connection between the BCL 300i 301i and a PC/laptop. Notice! Notes on the use of the webConfig tool can be found in chapter 9 "Leuze webConfig tool" on page 102 Leuze electronic 300i \ BCL 301i...
• Code GS1 Data Bar OMNIDIRECTIONAL • Code GS1 Data Bar LIMITED • Code GS1 Data Bar EXPANDED Deviations from these settings must be set via the webConfig tool. See "Leuze webConfig tool" on page 102. 300i \ BCL 301i Leuze electronic...
Deviations from these settings must be set via the webConfig tool. See "Leuze webConfig tool" on page 102. Notice! Permissible values for the network address in the Leuze multiNet plus are 1 … 31. Make certain that a different address is assigned to each multiNet plus participant. Leuze electronic 300i \ BCL 301i...
The two possibilities for the latter are Standard (corre- sponds to the standard for the selected code type/symbology) and not Standard. Define at least one code type with the desired settings. • Via webConfig: Configuration -> Decoder 300i \ BCL 301i Leuze electronic...
Page 113
Configuration of up to 3 different sorting criteria. Sorting by physical data and content of the read bar codes. • Formatting of the data output for the HOST. • Formatting of the data output for the display. Leuze electronic 300i \ BCL 301i...
• stop decoding after a maximum reading gate time • stop decoding via the completeness mode, if: • the maximum number of bar codes to be decoded has been decoded • a positive reference code comparison has taken place. 300i \ BCL 301i Leuze electronic...
Configure the connected switching outputs according to your requirements. To do this, first set the I/O mode to Output and then configure the switching behavior: • Via webConfig: Configuration -> Device -> Switching inputs/outputs Leuze electronic 300i \ BCL 301i...
301i (reconnect the voltage supply). The configuration is now imported from the external parameter memory of the connection hood and the BCL 300i \ BCL 301i is immediately operational without any further config- uration. 300i \ BCL 301i Leuze electronic...
Most online commands are acknowledged by the BCL 300i \ BCL 301i and any requested data returned. For commands that are not acknowledged, command execution can be observed or monitored directly on the device. Leuze electronic 300i \ BCL 301i...
Software reset Command ’H’ Carries out a software reset. The device is restarted and reinitialized, Description leaving it in the same state as when the supply voltage is switched on. Parameter Acknowledgment ’S’ (start signal) 300i \ BCL 301i Leuze electronic...
Page 119
GS1 DataBar OMNIDIRECTIONAL ’14’ GS1 DataBar LIMITED ’15’ GS1 DataBar EXPANDED Number of digits of the read code Contents of the decoded label. A ↑ appears if the label was zzzzzz: not correctly read. Leuze electronic 300i \ BCL 301i...
Page 120
EAN Addendum ’11’ Codabar ’12’ Code 93 ’13’ GS1 DataBar OMNIDIRECTIONAL ’14’ GS1 DataBar LIMITED ’15’ GS1 DataBar EXPANDED Contents of the decoded label. A ↑ appears if the label zzzzzz: was not correctly read. 300i \ BCL 301i Leuze electronic...
Page 121
’+’: Starts the adjustment mode. Parameter ’-’: Ends the adjustment mode. ’yyy_zzzzzz’ yyy: Reading quality in %. A high process availability is Acknowledgment ensured at read qualities > 75%. zzzzzz: Bar code information. Leuze electronic 300i \ BCL 301i...
Page 122
’1’ Invalid command ’2’ Insufficient memory for reference code ’3’ Reference code has not been saved ’4’ Reference code invalid Input = ’RS130678654331’ (Code 1 (1), RAM only (3), UPC (06), code Example information) 300i \ BCL 301i Leuze electronic...
Page 123
After each reading via an ’RTy’ command, explicitly switch off the function again since failure to do so will interfere with other commands as well as prevent execution of a new ’RTx’ command. Leuze electronic 300i \ BCL 301i...
Page 124
Defined reference code no. Acknowledgment ’1’ (Code 1) ’2’ (Code 2) Memory location for reference code ’0’ RAM+EEPROM, ’3’ RAM only Defined code type (see command ’CA’) Defined code information (1 … 63 characters) 300i \ BCL 301i Leuze electronic...
The command deactivates decoding. This command can be used to deactivate the reading gate. Following deactivation, the read result is Description output. Because the reading gate was manually deactivated and, thus, no GoodRead criterion was met, a NoRead is output. Parameter Acknowledgment None Leuze electronic 300i \ BCL 301i...
(e.g., inverted logic and a state of High cor- responds to a voltage of 0V at the switching output). Parameter ’OA?’ ’OA S1=<a>;S2=<a>’ <a> State of the switching outputs ’0’ Acknowledgment ’1’ High ’I’ Configuration as switching input ’P’ Passive configuration 300i \ BCL 301i Leuze electronic...
Page 127
The logic state is output, i.e., an inverted logic is taken into account (e.g., inverted logic and a state of High corresponds to a voltage of 0V at the switching output). ’OD<a>’ Parameter <a> Selected switching output [1, 2], unit (dimensionless) Acknowledgment None Leuze electronic 300i \ BCL 301i...
Page 128
’OF [S1=<a>][;S2=<a>]’ <a> Function of the switching input/ output, unit [dimensionless]’ Parameter ’I Switching input ’O’ Switching output ’P’ Passive ’OF=<bb>’ <bb> Status acknowledgment ’00’ Acknowledgment ’01’ Syntax error ’02’ Parameter error ’03’ Other error 300i \ BCL 301i Leuze electronic...
’PS=<aa>’ <aa> Status acknowledgment, unit [dimensionless] ’00’ ’01’ Syntax error Acknowledgment ’02’ Impermissible command length ’03’ Reserved ’04’ Reserved ’05’ Reserved ’06’ Impermissible combination, source type - target type Leuze electronic 300i \ BCL 301i...
Page 130
<Address> Relative address of the data within the data set ’aaaa’ Four-digit, unit [dimensionless] <Data length> Length of the parameter data to be transferred ’bbbb’ Four-digit, unit [length in bytes] <BCC> Check sum calculated as specified under BCC type 300i \ BCL 301i Leuze electronic...
Page 131
Impermissible number of data requested ’06’ Requested data does not (any longer) fit in the transmis- sion buffer ’07’ Impermissible address value ’08’ Read access after end of data set ’09’ Impermissible QPF data set type Leuze electronic 300i \ BCL 301i...
Page 132
Relative address of the data within the data set ’aaaa’ Four-digit, unit [dimensionless] <P.value> Parameter value of the -bb- parameter stored at this address. The parameter set data is converted from HEX format to a 2-byte-ASCII format for transfer. 300i \ BCL 301i Leuze electronic...
Page 133
Command ’PD’ ’PS=<aa>’ <aa> Status acknowledgment, unit [dimensionless] ’0’ No difference Acknowledgment ’1’ Syntax error negative ’2’ Impermissible command length ’6’ Impermissible combination, parameter set 1 and parameter set 2 ’8’ Invalid parameter set Leuze electronic 300i \ BCL 301i...
Page 134
<P.value> Parameter value of the -bb- parameter stored at this address. The parameter set data is converted from HEX format to a 2-byte-ASCII format for transfer. <BCC> Check sum calculated as specified under BCC type 300i \ BCL 301i Leuze electronic...
Page 135
Impermissible value for checksum type Acknowledgment ’04’ Invalid check sum received ’05’ Impermissible data length ’06’ Invalid data (parameter limits violated) ’07’ Invalid start address ’08’ Invalid parameter set ’09’ Invalid parameter set type Leuze electronic 300i \ BCL 301i...
Avoid EMC coupling caused by power cables laid parallel to device lines. Check max. network expansion as a function • Overall network expansion of the max. cable lengths exceeded Table 12.2: Interface error 300i \ BCL 301i Leuze electronic...
Page 137
Customer data (please complete) Device type: Company: Contact partner / department: Phone (direct): Fax: Street / No: ZIP code/City: Country: Leuze Service fax number: +49 7021 573 - 199 Leuze electronic 300i \ BCL 301i...
M optics, display and heating 50116187 300i O F 100 D H with F optics, display and heating 50116181 300i O L 100 D H with L optics, display and heating 50116184 Table 13.2: Type overview BCL 300i Leuze electronic 300i \ BCL 301i...
M optics, display and heating 50116280 301i O F 100 D H with F optics, display and heating 50116274 301i O L 100 D H with L optics, display and heating 50116277 Table 13.3: Type overview BCL 301i 300i \ BCL 301i Leuze electronic...
301i 13.9 Reflector accessories for autoReflAct Type designation Description Part no. Reflective tape no. 4 / Reflective tape as reflector for autoReflAct operation 50106119 100 x 100 mm Table 13.9: Reflector for autoReflAct operation Leuze electronic 300i \ BCL 301i...
Contact your Leuze distributor or service organization should repairs be required. The addresses can be found on the inside of the cover and on the back. Notice! When sending devices to Leuze electronic for repair, please provide an accurate description of the error. 14.3...
CANCEL Invalid END OF MEDIUM End of medium SUBSTITUTE Substitution ESCAPE Escape FILE SEPARATOR File separator GROUP SEPARATOR Group separator RECORD SEPARATOR Record separator UNIT SEPARATOR Unit separator SPACE Space EXCLAMATION POINT Exclamation point Leuze electronic 300i \ BCL 301i...
Page 150
Number Number COLON Colon SEMICOLON Semicolon < LESS THAN Less than EQUALS Equals > GREATER THAN Greater than QUESTION MARK Question mark COMMERCIAL AT Commercial AT Capital letter Capital letter Capital letter Capital letter 300i \ BCL 301i Leuze electronic...
Page 151
CLOSING BRACKET Closing bracket CIRCUMFLEX Circumflex UNDERSCORE Underscore ‘ GRAVE ACCENT Grave accent Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Leuze electronic 300i \ BCL 301i...
Page 152
Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter OPENING BRACE Opening brace VERTICAL LINE Vertical line CLOSING BRACE Closing brace TILDE Tilde DELETE (RUBOUT) Delete 300i \ BCL 301i Leuze electronic...