8.5

Setting tape selection via the webConfig tool

 In the webConfig tool (CONFIGURATION > MEASUREMENT DATA > Bar code tape), set the
selection
parameter according to the used bar code tape grid; see chapter 9.3.2 "CONFIGURATION
function".
• 30 mm grid
• 40 mm grid
8.6

Configuration via the switches of the connection hood

The following settings can be configured via the operational controls of connection hoods MS 307 and
MK 307:
• Resolution of the position value
• Data encoding of the measurement values:
• Speed monitoring via switching output (SWIO1)
The settings made via the operational controls of the connection hood can alternatively be con-
figured via the webConfig tool; see chapter 9.3.2. To do this, rotary switch S2 must be set to
switch position
If rotary switch S2 is set to switch position
1
2
Figure 8.2:
Operational controls of connection hood MS 307
Leuze electronic
0
.
1
2
Slide switch S1
Factory setting: Gray encoding
Hexadecimal rotary switch S2
Factory setting:
0
, i.e., configuration via the webConfig tool
Gray
binary
or
0
, slide switch S1 is not evaluated.
BPS 307i
Basic configuration
Tape
54