Leuze electronic BCL 248i Operating Instructions Manual page 66

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Input data
New result
Result state
Further results
in the buffer
Buffer overflow
New decoding
Result state
Waiting for ac-
knowledgment
Input data length
1 byte
Output data
None
Comments
The following bits are constantly updated, i.e. they are updated immediately after the respective event oc-
curs:
Reading gate state
• Further results in the buffer
• Buffer overflow
• Waiting for acknowledgment
All other flags refer to the currently output decoding result.
If the input data is reset to the initial value (see chapter 8.8.3 "Module 30 – Data formatting"), the following
bits are deleted:
• New result
• Result state
All others remain unchanged.
Data reset behavior
Upon data reset (see chapter 8.7.1 "Module 10 – Activations") the input data is deleted, except for the
reading gate status and the two toggle bits.
Leuze electronic GmbH + Co. KG
Description
The signal indicates whether a new de-
coding has occurred.
The signal indicates whether the bar code
has been read successfully.
The signal indicates whether further re-
sults are in the buffer.
The signal indicates that result buffers are
occupied and the decoder rejects data.
Toggle bit indicates whether decoding has
occurred.
Toggle bit indicates that the bar code has
not been read.
This signal represents the internal state of
the control.
Addr.
0.1
0.2
0.3
0.4
0.5
0.6
0.7
BCL 248i
Data
Value range
type
Bit
0: No
1: Yes
Bit
0: Successful
reading
1: NOREAD
Bit
0: No
1: Yes
Bit
0: No
1: Yes
Bit
0 > 1: New re-
sult
1 > 0: New re-
sult
Bit
0 > 1:
NOREAD
1 > 0:
NOREAD
Bit
0: Base state
1: Control wait-
ing for ac-
knowledgment
from the
IO controller
Initial
value
0
0
0
0
0
0