Text passages with this symbol provide you with further information. Symbol for action steps Text passages with this symbol instruct you to perform actions. Table 1.3: Terms and abbreviations Bar code reader Code reconstruction technology Leuze electronic BCL 600i/BCL 601i...
The device must not be tampered with and must not be changed in any way. The device must not be opened. There are no user-serviceable parts inside. Repairs must only be performed by Leuze electronic GmbH + Co. KG. Competent persons Connection, mounting, commissioning and adjustment of the device must only be carried out by competent persons.
Safety Exemption of liability Leuze electronic GmbH + Co. KG is not liable in the following cases: • The device is not being used properly. • Reasonably foreseeable misuse is not taken into account. • Mounting and electrical connection are not properly performed.
Page 9
EN 60825-1:2007 AVOID EXPOSURE – LASER RADIATION IS EMITTED FROM THIS APERTURE Laser aperture Laser warning sign Laser information sign with laser parameters Figure 2.2: Laser aperture, laser warning and information signs - oscillating-mirror scanner Leuze electronic BCL 600i/BCL 601i...
2/5 Interleaved, Code 39, Code 128, EAN 8/13 etc., as well as codes from the GS1 DataBar family. Bar code readers of the BCL 600i series are available in various optics models as well as line scanners and oscillating mirrors and also optionally as heated models.
Page 12
• Automatic monitoring of the read quality with autoControl • Automatic recognition and setting of the bar code type using autoConfig • Reference code comparison • Optional heating models to -35 °C • Heavy-duty housing of degree of protection IP 65 Leuze electronic BCL 600i/BCL 601i...
M 12 connection technology USB interface Dovetail mounting M4 mounting thread Figure 3.2: Device construction Connection technology The bar code readers are connected using variously coded M 12 connectors. This ensures unique connec- tion assignments. Leuze electronic BCL 600i/BCL 601i...
Device description The additional USB interface is used for configuring the device. The two product series BCL 600i and BCL 601i differ in their interfaces and in their function as multiNet plus master or slave. Table 3.1: BCL 600i/BCL 601i interfaces...
• No data on the host interface Flashes red Device ok, warning set • Bar code reading possible • Temporary operating fault Red, Device error / parameter enable continuous light • No bar code reading possible Leuze electronic BCL 600i/BCL 601i...
The delivery contents of the external parameter memory include the hood with integrated connectors with unscrewable cover and the USB memory stick. For transferring the configuration with the aid of the external parameter memory see chapter 6.2. Leuze electronic BCL 600i/BCL 601i...
Figure 4.1: Possible bar code orientation The BCL 600i / BCL 601i can be operated and configured using the integrated webConfig tool via the USB service interface; alternatively, the bar code readers can be adjusted using configuration commands via the host/service interface.
With the autoConfig function, the device offers an extremely simple and convenient configuration option to users who only want to read one code type (symbology) with one number of digits at a time. Leuze electronic BCL 600i/BCL 601i...
Afterward, bar codes with the same code type and number of digits are recognized and decoded. Stand-alone connection The bar code readers of the BCL 600i series can be operated as single “stand-alone” devices. The device features multiple M 12 connectors / sockets for the electrical connection of the supply voltage, the interface and the switching inputs and outputs.
(thus, all multiNet slave are included in multiScan operation). Heater For low-temperature applications to min. -35°C (e.g. in cold storage), the bar code readers of the BCL 600i series can optionally be permanently fitted with a built-in heating and these bar code readers purchased as separate device models.
In this way, the device can also scan larger areas or spaces for bar codes. The reading field height (and the scan line length useful for evaluation) depends on the reading distance due to the optical opening angle of the oscillating mirror. Leuze electronic BCL 600i/BCL 601i...
In order to read arbitrarily oriented bar codes on an object, at least 2 bar code readers are necessary. If the bar code is not printed over-square, i.e. bar length > code length, bar code readers with integrated code reconstruction technology are necessary. Leuze electronic BCL 600i/BCL 601i...
Total reflection occurs whenever the laser light of the bar code reader is directly incident on the surface of the bar code at an angle of 90°. The light directly reflected by the bar code may overload the bar code reader and thereby cause non-readings! Leuze electronic BCL 600i/BCL 601i...
The optimum alignment of the device is accomplished when the scan line scans the bar code bars almost at a right angle (90°). All reading angles that are possible between the scan line and bar code must be taken account (see figure 6.3). Leuze electronic BCL 600i/BCL 601i...
Remove the external parameter memory from the defective device by unscrewing the protection hood. Mount the external parameter memory on the new device. Install and start up the new device. The following message appears on the display again: • Memory stick connected: Export internal configuration? Leuze electronic BCL 600i/BCL 601i...
Page 27
Make sure you select Cancel. Otherwise, the configuration in the external parameter memory is lost! The configuration is now imported from the external parameter memory and the device is immediately operational without any further configuration. Leuze electronic BCL 600i/BCL 601i...
Bus Out RS 485, M 12 socket (B-coded) HOST/BUS in, M 12 connector (B-coded) PWR, M 12 connector (A-coded) Figure 7.1: Connections of the device Described in detail in the following are the individual connections and pin assignments. Leuze electronic BCL 600i/BCL 601i...
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (National Electric Code). CAUTION The bar code readers of the BCL 600i series are designed in accordance with protection class III for supply by PELV (protective extra-low voltage with reliable disconnection). Connecting functional earth FE ...
Page 30
60 mA at +10 … +30 V DC in normal operation! By default, the two switching inputs/outputs SWIO_3 and SWIO_4 are configured so that switch- ing input SWIO_3 activates the reading gate and switching output SWIO_4 switches on “No Read”. Leuze electronic BCL 600i/BCL 601i...
IP 65 is achieved only if the connectors and caps are screwed into place. Alternatively, a parameter memory in the form of a USB memory stick certified by Leuze electronic GmbH + Co. can be connected to the provided USB service interface. With this Leuze memory stick, degree of protection IP 65 is also ensured.
Page 32
2, and pin 2 of the bar code reader is, at the same time, configured as an output (and not as an input), the switching output malfunctions. NOTICE The maximum input current must not exceed 8 mA! Leuze electronic BCL 600i/BCL 601i...
HOST / BUS IN for BCL 600i The BCL 600i makes either the RS 232 or RS 422 interface available as host interface. This is selected via the display or the “webConfig” configuration software. The pin assignments change depending on the selected interface type (see table 7.4, see figure 7.10 and see figure 7.11).
Page 34
This interface is physically looped through to the BUS OUT RS 485 socket. With its RS 485 interface, the BCL 601i is suitable for use in the Leuze multiNet plus scanner network. Figure 7.12: HOST/BUS IN, M 12 connector (B-coded) Leuze electronic BCL 600i/BCL 601i...
Ensure adequate shielding. The entire interconnection cable must be shielded and earthed. The signal lines must be stranded in pairs. Termination of the RS 485 interface on the master (BCL 600i) The RS 485 interface must always be terminated externally on the master via a T-connector and a termi- nating resistor (see chapter 16 "Ordering information and accessories").
Electrical connection The BCL 600i can only participate as a slave in the Leuze multiNet plus on the BUS OUT socket and via an external M 12 T-connector (see chapter 7.8.3 and see figure ). Termination of the RS 485 interface (BCL 601i) The device operates as slave in the Leuze multiNet plus network.
Figure 7.14: Leuze multiNet plus system topology With the aid of a BCL 600i network master, up to 31 bar code readers can be networked. For this purpose, each participating device is assigned the respective station address via the display and the control panel.
Last slave address Unlike the slaves, the display of the BCL 600i is not used to set the network address (the master always has the address 00), but the last slave address, i.e. the number of the most significant slave. This “informs”...
Slave address The BCL 600i display has an important function for setting the network address. The network address, i.e. the corresponding station number of the slave, is set via the display. The address which is set must be > 0 since the master always has address 0 (Adr.00).
Decoder table In the Decoder table submenu, 4 different code type definitions can be stored. Bar codes that have been read can only be decoded if they correspond to one of the definitions stored here. Leuze electronic BCL 600i/BCL 601i...
Page 41
If Standard is set, the check digit method intended for the respec- tive code type is used. Check digit transmis- Standard Standard sion Not standard Specifies whether the check digit is transmitted. Standard means that the transmission matches the standard intended for the respective code type. Leuze electronic BCL 600i/BCL 601i...
Page 42
0 to 64 characters Number of digits 0 to 64 characters Reading reliability Value from 2 to 100 Check digit method Same as decoder 1 Standard Check digit transmis- Same as decoder 1 Standard sion Leuze electronic BCL 600i/BCL 601i...
Page 43
Function No BCL600i function Reading gate Reading gate start/stop start/stop Reading gate stop -Reading gate start Teach reference code Autoconfig start/stop The function set here is carried out after the switching input is activated. Leuze electronic BCL 600i/BCL 601i...
Page 44
OFF / ON Signal delay Value from 0 to 65535 Pulse duration Value from 0 to 65535 Activation function 2 See switching input/output 1 Valid read result Deactivation function 2 See switching input/output 1 Reading gate start Leuze electronic BCL 600i/BCL 601i...
Page 45
Stand-alone device Stand-alone Network Master device Network Slave HOST / BUS IN Protocol type No protocol Framing protocol Framing protocol Framing protocol with acknowledgment muliNet Slave multiNet Master Interface Baud rate 110 ... 115200 Baud 9600 Leuze electronic BCL 600i/BCL 601i...
If the device is configured as stand-alone device or network master, the framing protocol defines how data is exchanged between the BCL 600i and the host. The framing protocol is a character-based protocol for the transmission of ASCII characters. It groups the characters to be transmitted into a datablock and frames the block with control characters. Var- ious block checking methods are optionally available for protecting the integrity of the data.
Menu description Service menu Diagnostics This menu item is used exclusively for service purposes by Leuze electronic. Status messages This menu item is used exclusively for service purposes by Leuze electronic. Actions menu Start decoding Here, you can perform a single reading via the display.
The PWR LED lights up red. You can now set individual parameters via the display. Press the Escape button twice to return to the main menu. Network configuration For information on network configuration see chapter 10 "Starting up the device - Configuration". Leuze electronic BCL 600i/BCL 601i...
Upon successful installation of the USB driver, an icon automatically appears on the desktop. To check: In the Windows device manager, a device called “Leuze electronic, USB Remote NDIS Network Device” appears under the “Network adapter” device class following successful USB registration.
Or alternatively: Open a browser on your PC and enter the following address: 192.168.61.100. This is the default Leuze service address for communication with bar code readers of the BCL 600i series. In both cases, the following start page appears on your PC.
Commissioning – Leuze electronic webConfig tool Module overview in the Configuration menu The adjustable parameters of the device are clustered in modules in the Configuration menu. Figure 9.2: Module overview in the webConfig tool The webConfig tool is completely contained in the firmware of the device. Depending on firmware version, the module overview may vary from that shown above.
10.3 BCL 600i operation As a first step, you need to set the communication parameters of the device. The BCL 600i can be oper- ated as stand-alone device, multiNet plus master or multiNet plus slave. You can make the necessary settings via the display or via the webConfig tool. The settings made by means of the webConfig tool are described here only briefly.
10.4). 10.3.3 Operation as multiNet plus master For operation as multiNet plus master, you must inform the BCL 600i of the maximum number of slaves to be managed. This is done via the Maximum number of slaves parameter. Set the Maximum number of slaves parameter to the desired value: Via webConfig: ...
Starting up the device - Configuration Furthermore, you must configure the BCL 600i in such a way that it can communicate with the superior host: Interface standard and communication parameters of the host interface: Select the desired interface standard (RS 232 / RS 422) and set the associated parameters: Via webConfig: ...
The two possibilities for the latter are Standard (corresponds to the standard for the selected code type/symbology) and not Standard. Define at least one code type with the desired settings. In the webConfig tool: Configuration -> Decoder Or alternatively in the display: Parameter -> Decoder table Leuze electronic BCL 600i/BCL 601i...
Page 56
By using the switching inputs/outputs of the device, external event-controlled functions can be imple- mented without assistance from the superior process control. For this purpose, the respective connection at the SW IN/OUT and POWER interfaces must be configured as a switching output. Leuze electronic BCL 600i/BCL 601i...
The device stores a copy of the current configuration in the external parameter memory. This copy is immediately updated when the configuration is changed via the display or by a superior host system (PC/ PLC) via online commands. Leuze electronic BCL 600i/BCL 601i...
Requests device version information Parameter Acknowledgment BCL 600i SM 100 V 1.3.8 2008-02-15 The first line contains the device type, followed by the device version number and version date. (The data which is actually displayed may vary from the val- ues given here.)
Page 59
Parameter Activates autoConfig Rejects the last code read Deactivates autoConfig and stores the decoded data in the cur- rent parameter set Leuze electronic BCL 600i/BCL 601i...
Page 60
The duration of the pauses has been stepped in such a way that they can be distinguished by the eye. Parameter Starts the adjustment mode. Ends the adjustment mode. Leuze electronic BCL 600i/BCL 601i...
Page 61
Example Input = RS130678654331 (Code 1 (1), RAM only (3), UPC (06), code informa- tion) Reference code teach-in Command Description This command enables a reference code to be defined quickly by reading an example label. Leuze electronic BCL 600i/BCL 601i...
Page 62
The command reads out the reference code defined in the device. If no parameters are specified, all defined codes are output. Parameter <reference code number> 1 … 2 value range of reference code 1 to 2 Leuze electronic BCL 600i/BCL 601i...
The command deactivates decoding. This command can be used to deacti- vate the reading gate. Following deactivation, the read result is output. Because the reading gate was manually deactivated and, thus, no GoodRead criterion was met, a NoRead is output. Parameter Acknowledgment None Leuze electronic BCL 600i/BCL 601i...
Copying the default parameters to the permanent memory and to the main memory Acknowledgment PS=<aa> <aa> Status acknowledgment, unit [dimensionless] Syntax error Impermissible command length Reserved Reserved Reserved Impermissible combination, source type - target type Leuze electronic BCL 600i/BCL 601i...
Page 65
Relative address of the data within the data set aaaa Four-digit, unit [dimensionless] <Data length> Length of the parameter data to be transferred bbbb Four-digit, unit [length in bytes] <BCC> Check sum calculated as specified under BCC type Leuze electronic BCL 600i/BCL 601i...
Page 66
Invalid check sum received Impermissible number of data requested Requested data does not (any longer) fit in the transmission buffer Impermissible address value Read access after end of data set Impermissible QPF data set type Leuze electronic BCL 600i/BCL 601i...
Page 67
Output of the parameter differences between the default parame- ter set and the operating parameter set saved in volatile memory Output of the parameter differences between the permanent parameter set and the operating parameter set saved in volatile memory Leuze electronic BCL 600i/BCL 601i...
Page 68
(factory parameter set) for initialization. This command can be used to edit the first two parameter sets (in permanent and volatile memory). A check sum can be used for reliable parameter transfer. Leuze electronic BCL 600i/BCL 601i...
Page 69
<P.value> Parameter value of the -bb- parameter stored at this address. The parameter set data is converted from HEX format to a 2-byte-ASCII format for transfer. <BCC> Check sum calculated as specified under BCC type. Leuze electronic BCL 600i/BCL 601i...
Page 70
Status acknowledgment, unit [dimensionless] Syntax error Impermissible command length Impermissible value for checksum type Invalid check sum received Impermissible data length Invalid data (parameter limits violated) Invalid start address Invalid parameter set Invalid parameter type Leuze electronic BCL 600i/BCL 601i...
NOTICE Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device. 12.2 Servicing 12.3 Disposing For disposal observe the applicable national regulations regarding electronic components. Leuze electronic BCL 600i/BCL 601i...
(FE) • Avoid EMC coupling caused by power cables laid parallel to device lines • Overall network expansion exceeded • Check max. network expansion as a func- tion of the max. cable lengths Leuze electronic BCL 600i/BCL 601i...
Monday to Friday 8.00 a.m. to 5.00 p.m. (UTC+1) E-mail: service.identify@leuze.de Return address for repairs: Service center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany 14.1 What to do should servicing be required? Please use this chapter as a master copy should servicing be required! Enter the contact information and fax the form together with your service order to the fax number given below.
Page 75
IEC 61000-6-2 (contains IEC 61000-4-2, -3, -4, -5 and -6) a) This is a Class A product. In a domestic environment this product may cause radio interference, in which case the oper- ator may be required to take adequate measures. Leuze electronic BCL 600i/BCL 601i...
15.2 Heating models of the bar code readers The devices of the BCL 600i series are optionally available as models with integrated heating. In this case, heating is permanently installed ex works. Self-installation on-site by the user is not possible! Features •...
Standard, M 12 ready-made cable is not usable (insufficient cable cross-section) Environmental data Operating tem- -35 °C … +40 °C perature range Storage temper- -20 °C … +70 °C ature range Leuze electronic BCL 600i/BCL 601i...
Standard, M 12 ready-made cable not usable (insufficient cable cross-section). Environmental data Operating tem- -35 °C … +40 °C perature range Storage temper- -20 °C … +70 °C ature range Leuze electronic BCL 600i/BCL 601i...
Technical data 15.3 Dimensioned drawings Optical axis M4, 7 mm deep M4, 6 mm deep Figure 15.1: Dimensioned drawing - line scanner Leuze electronic BCL 600i/BCL 601i...
Page 80
Technical data Optical axis Optical swivel range Opening angle M4, 7 mm deep M4, 6 mm deep Figure 15.2: Dimensioned drawing - oscillating-mirror scanner Leuze electronic BCL 600i/BCL 601i...
The zero position of the reading distance always refers to the front edge of the housing of the beam exit and is shown for the two housing types of the device (see figure 15.6). Leuze electronic BCL 600i/BCL 601i...
Page 83
Distance acc. to reading field curves Figure 15.6: Zero position of the reading distance Reading conditions for the reading field curves Table 15.13: Reading conditions Bar code type 2/5 Interleaved Ratio 1:2.5 ANSI specification Class A Reading rate > 75% Leuze electronic BCL 600i/BCL 601i...
Module = 0.3 mm: 400 mm - 800 mm (400 mm depth of field) Module = 0.35 mm: 400 mm - 900 mm (500 mm depth of field) Figure 15.8: Lateral reading field curve - Medium Density for oscillating-mirror scanner Leuze electronic BCL 600i/BCL 601i...
Module = 0.35 mm: 500 mm - 1200 mm (700 mm depth of field) Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) Figure 15.9: Reading field curve - Low Density for line scanner Leuze electronic BCL 600i/BCL 601i...
Module = 0.3 mm: 400 mm - 800 mm (400 mm depth of field) Module = 0.35 mm: 400 mm - 900 mm (500 mm depth of field) Figure 15.12:“Medium Density” reading field curve for oscillating-mirror scanners with heating Leuze electronic BCL 600i/BCL 601i...
Page 88
Module = 0.35 mm: 400 mm - 900 mm (500 mm depth of field) Figure 15.13:Lateral “Medium Density” reading field curve for oscillating-mirror scanners with heating The reading field curve applies for the reading conditions stated above (see table 15.13). Leuze electronic BCL 600i/BCL 601i...
Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) Figure 15.14:“Low Density” reading field curve for line scanner with heating The reading field curve applies for the reading conditions stated above (see table 15.13). Leuze electronic BCL 600i/BCL 601i...
Module = 0.35 mm: 500 mm - 1200 mm (700 mm depth of field) Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) Figure 15.15:“Low Density” reading field curve for oscillating-mirror scanners with heating Leuze electronic BCL 600i/BCL 601i...
Page 91
Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) 2/5l Figure 15.16:Lateral “Low Density” reading field curve for oscillating-mirror scanners with heating The reading field curve applies for the reading conditions stated above (see table 15.13). Leuze electronic BCL 600i/BCL 601i...
L: Ultra Low Density (very large distances) Beam exit: 0 = Perpendicular 2 = Front With heating A list with all available device types can be found on the Leuze electronic website at www.leuze.com. 16.2 Type overview Table 16.2: BCL 600i / BCL 601i part numbers Part no.
Part designation Description 50132848 BCL 600i OF 100 Oscillating-mirror scanner, Low Density 50132849 BCL 600i SF 102 H Line scanner, beam exit at the front with heating, Low Density 50132850 BCL 600i OF 100 H Oscillating-mirror scanner with heating, Low Density 16.3...
Page 94
BUS OUT USB cables 50107726 KB USB-Service USB service cable External parameter memory 50108833 USB Memory Set External USB parameter memory Mounting devices 50027375 BT 56 Mounting device for rod 50111224 BT 59 Mounting bracket Leuze electronic BCL 600i/BCL 601i...
The bar code readers of the BCL 600 series have been developed and manufactured in accordance with the applicable European standards and directives. The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen, possesses a certi- fied quality assurance system in accordance with ISO 9001.
SYNCHRONOUS IDLE Synchronization EOF TRANSM. BLOCK End of data transmission block CANCEL Invalid END OF MEDIUM End of medium SUBSTITUTE Substitution ESCAPE Escape FILE SEPARATOR File separator GROUP SEPARATOR Group separator RECORD SEPARATOR Record separator Leuze electronic BCL 600i/BCL 601i...
Page 97
Slant Number Number Number Number Number Number Number Number Number Number COLON Colon SEMICOLON Semicolon < LESS THAN Less than EQUALS Equals > GREATER THAN Greater than QUESTION MARK Question mark COMMERCIAL AT Commercial AT Leuze electronic BCL 600i/BCL 601i...
Page 98
Capital letter Capital letter Capital letter Capital letter OPENING BRACKET Opening bracket REVERSE SLANT Reverse slant CLOSING BRACKET Closing bracket CIRCUMFLEX Circumflex UNDERSCORE Underscore ‘ GRAVE ACCENT Grave accent Lower case letter Lower case letter Leuze electronic BCL 600i/BCL 601i...
Page 99
Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter OPENING BRACE Opening brace VERTICAL LINE Vertical line CLOSING BRACE Closing brace TILDE Tilde DELETE (RUBOUT) Delete Leuze electronic BCL 600i/BCL 601i...