Starting up the device - Configuration
Parameter
Tab. 8.44:
Parameters for module 80
Parameter
Sort criterion 1
Sort direction 1
Sort criterion 2
Sort direction 2
Sort criterion 3
Sort direction 3
Parameter length
3 bytes
Input data
None
Output data
None
Leuze electronic GmbH + Co. KG
Description
Specifies the criterion ac-
cording to which sorting
takes place.
Specifies the sorting di-
rection.
Specifies the criterion ac-
cording to which sorting
takes place.
Specifies the sorting di-
rection.
Specifies the criterion ac-
cording to which sorting
takes place.
Specifies the sorting di-
rection.
Addr. Data
Value range
type
0.0 ...
BitArea
0: No sorting
 0.6
1: Sorting according to scan
number
2: Sorting according to posi-
tion in the scanning beam
4: Sorting according to the
decoding quality
5: Sorting according to the
bar code length
6: Sorting according to the
code type number
7: Sorting according to the
decoding direction
8: Sorting according to the
bar code content
9: Sorting according to time
10: Sorting according to
scanning duration
11: Sorting according to the
code list (in which the en-
abled bar codes are listed)
12: Sorting according to the
identifier list
0.7
Bit
0: In ascending order
1: In descending order
1.0 ...
BitArea
See sorting criterion 1
 1.6
1.7
Bit
See sorting direction 1
2.0 ...
BitArea
See sorting criterion 1
 2.6
2.7
Bit
See sorting direction 1
BCL 248i
Default
0
0
0
0
0
0
94