Starting up the device - Configuration
8.6.3
Module 7 – Code reconstruction technology
PROFINET-IO module identifier
Module ID: 1007
Submodule ID: 1
Description
Module for supporting the code reconstruction technology
Parameter
Tab. 8.5:
Parameters for module 7
Parameter
Maximum width
ratio
Minimum num-
ber of elements
Code fragment
mode
Processing end
at end of label
Parameter length
4 bytes
Input data
None
Output data
None
NOTICE
Processing end at end of label
If this parameter is set, a decoded bar code is only completely decoded after the scanning beam
has exited the entire bar code. This mode is useful if the quality of the bar code is to be as-
sessed, since more scans are now available for the quality evaluation of the bar code.
This parameter should be set if the AutoControl function is activated (see chapter 8.15.3 "Mod-
ule 92 – AutoControl"). If the parameter is not set, the bar code is immediately decoded and pro-
cessed further as soon as all necessary bar code elements are available
Leuze electronic GmbH + Co. KG
Description
The maximum width ratio is used to deter-
mine the light zones. The light zones iden-
tify the beginning or end of patterns.
A pattern must have at least this minimum
number of duo-elements, i.e. no patterns
which have fewer duo-elements.
This parameter can be used to switch CRT
mode on and off.
If this parameter is set, a decoded bar
code is only completely decoded after the
scanning beam has exited the entire bar
code.
Addr
.
0
1 ...
2
3.0
3.2
BCL 248i
Data type
Value
range
UNSIGNED8 0 ... 255
UN-
2 ... 400
SIGNED16
Bit
0:
Switched
off
1:
Switched
on
Bit
0:
Switched
off
1:
Switched
on
Default
13
6
1
0
59