Starting up the device - Configuration
Description
The module contains the display of the device status as well as control bits for triggering a reset or putting
the device into standby mode.
Parameter
None
Input data
Tab. 8.33:
Input data for module 60
Input data
Device status
Input data length
1 byte
Output data
Tab. 8.34:
Output data for module 60
Output data
System reset
Standby
Output data length
1 byte
NOTICE
When resetting the data (see chapter 8.7.1 "Module 10 – Activations") the input data of this
module is not deleted.
Leuze electronic GmbH + Co. KG
Description
This byte represents the
device status.
Description
The control bit triggers a
system reset if the level
changes from 0 to 1.
Analogous to command H,
activation of this bit trig-
gers a restart of all elec-
tronics, incl. a restart of
the PROFINET-IO stack.
Activates the standby
function
Addr. Data type
0
UNSIGNED8 1: Initialization
Addr. Data type
0.6
Bit
0.7
Bit
BCL 248i
Value range
10: Standby
11: Service
12: Diagnosis
13: Parameter Enabled
15: Device is ready
0x80: Error
0x81: Warning
Value range
0: Run
0 > 1: Reset
0: Standby off
1: Standby on
Initial
value
0
Initial
value
0
0