Module 82 - Reference Code Comparator 2 - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Parameter
Reference code
completeness
comparison
Parameter length
8 bytes
Input data
None
Output data
None
8.14.2 Module 82 – Reference code comparator 2
PROFINET-IO module identifier
Module ID: 1082
Submodule ID: 1
Description
The module defines the mode of operation of reference code comparator 2.
Parameter
Tab. 8.46:
Parameters for module 82
Parameter
Output function
after reference
bar code compar-
ison
Linking logic for
reference code
output signal
Output for refer-
ence code com-
parison
Leuze electronic GmbH + Co. KG
Description
If this parameter is set,
the basic condition for a
positive reference code
comparison is that all
mandatory bar codes
that are to be read within
a reading gate were ac-
tually read. If this condi-
tion is not satisfied, no
positive reference code
comparison is achieved.
Description
This parameter specifies
the associated output
linkage after a reference
bar code comparison.
This parameter specifies
the linking logic for the
reference code output
signal.
This parameter specifies
whether a bar code
length comparison
should be carried out.
Addr. Data type
7.0
Bit
Addr. Data type
0
UNSIGNED8 0: No function
1
UNSIGNED8 0: Length and type and
2
UNSIGNED8 0: Length ignored
BCL 248i
Value range
0: Completeness com-
parison switched off.
1: Completeness com-
parison switched on.
Value range
1: Comparison function 1
2: Comparison function 2
3: Comparison function 1
AND 2
4: Comparison function 1
OR 2
ASCII
1: Length and (type or
ASCII)
2: (Length or type) and
ASCII
3: Length or type or
ASCII
1: Comp. o.k., if length
unequal
2: Comp. o.k., if length
equal
Default
0
Default
1
0
2
97

Advertisement

Table of Contents
loading

Table of Contents