Module 13 - Fragmented Read Result; Module 14 - Interlinked Read Result - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
8.7.4
Module 13 – Fragmented read result
PROFINET-IO module identifier
Module ID: 1013
Submodule ID: 1
Description
The module defines the transfer of fragmented reading results. To occupy few I/O data, the read results
may be split into several fragments with this module. The fragments can then be transmitted one after an-
other with a handshake.
Parameter
Tab. 8.11:
Parameters for module 13
Parameter
Fragment length The parameter defines the maximum length
Parameter length
1 byte
Input data
Tab. 8.12:
Input data for module 13
Input data
Fragment num-
ber
Remaining frag-
ments
Fragment size
Input data length
2 byte consistent
Output data
None
8.7.5
Module 14 – Interlinked read result
PROFINET-IO module identifier
Module ID: 1014
Submodule ID: 1
Description
This module is used to switch to a mode in which all decoding results within one reading gate are combined
into a single read result.
Leuze electronic GmbH + Co. KG
Description
of the bar code information per fragment.
Description
Current fragment number
Number of fragments which still have to be
read for a complete result.
Fragment length, always corresponds to the
configured fragment length, except for the
last fragment.
Addr.
0
Addr.
0.0 ... 0.
3
0.4 ... 0.
7
1
BCL 248i
Data type
Value
range
UN-
1 ... 128 0
SIGNED8
Data type
Value
range
BitArea
0 ... 15
BitArea
0 ... 15
UN-
0 ... 128 0
SIGNED8
Default
Initial
value
0
0
64