Fast commissioning / operating principle
Voltage supply and switching inputs/outputs
The voltage supply (10 ... 30VDC) is connected at the PWR M12 connector.
Available at both the PWR M12 connector as well as at the SW IN/OUT M12 socket are four
freely programmable switching inputs/outputs for custom adaptation to the respective
application. Detailed information on this topic can be found in chapter 7.2.1 and chapter
7.2.3 (for the BCL 500
Stand-alone operation
During stand-alone operation of the BCL 500
connected to HOST/BUS IN. Please make certain that the correct interface is used on the
primary system. The standard setting of the BCL 500
Network operation in the Leuze multiNet plus
In Leuze multiNet plus network operation, the primary system (PC/PLC) is connected to the
host interface of the BCL 500
occurs via BUS OUT.
If BUS OUT is not used for the connection to the next participant, the Leuze multiNet plus
network must be terminated with an M12 terminating resistor at the last participant (see
chapter 13.3 "Accessory terminating resistor").
3.4

Starting the device

Connect the supply voltage +10 ... 30VDC (typ. +24VDC); the BCL
starts up and the barcode reading window appears on the display:
As a first step, you need to set the operating mode of the BCL 500
operated as a stand-alone device, multiNet plus master, or multiNet plus slave.
You can make the necessary settings via the display or via the webConfig tool. Provided
here is only a brief description of the settings via the webConfig tool; detailed information
can be found in chapter 10.
Select the desired operating mode
• Via webConfig:
Configuration -> Communication -> Overview
Operation as a multiNet plus master
Set the max. slave number parameter to the desired value:
• Via webConfig:
Configuration -> Communication -> BUS OUT -> Protocol
16
i
) and in chapter 7.3.1 and chapter 7.3.3 (for the BCL 501
i
, the bus connection to the next participant, e.g. a BCL 501
By default, parameter enabling is deactivated and you can-
31
not change any settings. If you wish to carry out the config-
uration via the display, you must activate parameter
enabling. Further information can be found in chapter
"Parameter enabling" on page 103
i
BCL 500
\ BCL 501
i
, the host interface of the primary system is
i
for the host interface is RS 232.
i
i
).
500i
\ BCL
501i
i
i
. The BCL 500
can be
Leuze electronic
i
,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl501i

Table of Contents