Service - Usb Interface (Type A); Sw In/Out - Switching Input/Switching Output - Leuze electronic 50126970 Original Operating Instructions

Table of Contents

Advertisement

7.3
SERVICE – USB interface (type A)
3
2
4
1
Figure 7.5:
Service, USB, type A
Table 7.2:
Pin
Name
1
VB
2
D-
3
D+
4
GND
NOTICE
Maximum load of the +5 V DC supply voltage of the USB interface is 200 mA!
 Ensure adequate shielding.
The entire interconnection cable must absolutely be shielded acc. to the USB specifications. Cable
length must not exceed 3 m.
 Use the Leuze-specific USB service cable (see chapter 16 "Ordering information and accessories") for
the connection and use a service PC to configure.
NOTICE
IP 65 is achieved only if the connectors and caps are screwed into place. Alternatively, a parameter
memory in the form of a USB memory stick certified by Leuze electronic GmbH + Co. can be connected
to the provided USB service interface. With this Leuze memory stick, degree of protection IP 65 is also
ensured.
7.4
SW IN/OUT – Switching input/switching output
5
2
3
1
4
Figure 7.6:
SW IN/OUT, M12 socket (A-coded)
Table 7.3:
Pin
Name
1
VOUT
2
SWIO_
1
3
GND
Leuze electronic
Pin assignments of SERVICE – USB interface
Comment
Positive supply voltage +5 V DC
Data -
Data -
Ground
FE
Pin assignment SW IN/OUT
Comment
Voltage supply for sensors
(VOUT identical to VIN at PWR IN)
Configurable switching input / output 1
GND for the sensors
BCL 608i
Electrical connection
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl 608iBcl 600i series501269725013283250132833