Electrical connection

CAUTION
Safety notices
 The bar code reader is completely sealed and must not be opened.
 Do not try to open the device under any circumstances, as this voids both degree of protection IP 54
and the warranty.
 Before connecting the device, be sure that the supply voltage agrees with the value printed on the
name plate.
 Connection of the device and maintenance work while under voltage must only be carried out by a
qualified electrician.
 The power supply unit for the generation of the supply voltage for the bar code reader and the corre-
sponding connection units must have a secure electrical insulation according to IEC 60742 (PELV).
For UL applications: only for use in "class 2" circuits according to NEC.
 If faults cannot be corrected, the device should be removed from operation and protected against pos-
sible commissioning.
5.1

Voltage supply

The bar code reader is designed for connection to a 5 V supply voltage.
• +5 V DC (red)
• GND (violet)
Available as an accessory is an adapter circuit board with spring terminals and 9-pin SUB-D socket; see
chapter 12.2 "Accessories".
• With the adapter circuit board, the conductors of the connection cable can be contacted via the
spring terminals and connected to the PC via the 9-pin SUB-D socket with an RS 232 interconnec-
tion cable.
• With the adapter circuit board, the voltage supply from 10 ... 30 V DC can be fed in via spring termi-
nals or, alternatively, 5 V DC can be fed in via a micro USB connector.
5.2

Pin assignment of the connection cable

Wire
Assignment
Red
+5V DC
Violet
GND
Black
SW OUT
Orange
SW IN
White
RS 232 RxD
Green
RS 232 TxD
5.3

Switching input/Switching output

The bar code reader is provided with a switching input and a switching output.
• The switching input is used to trigger reading.
• The switching output signals successful code reading.
5.3.1

Switching input

By means of the SW IN switching input connection, you can trigger a read process in the standard setting
(low = active) with the connection SW IN (orange) and GND (violet). We recommend wiring a 2.2 kΩ "pull-
up" resistor as defined cable termination; see figure 5.1.
Leuze electronic
Description
Operating voltage 5V DC
Operating voltage 0V DC / reference ground
Switching output
Switching input