Part 9: Review on Replacement of Optional Peripheral Equipment
6.4 MR-J4-Series EMC Filter (Recommended) (400 V class)
It is recommended that one of the following filters be used to comply with EN EMC directive. Some EMC
filters have large in leakage current.
6.4.1 Combination with the servo amplifier
Servo amplifier
MR-J4-60_4(-RJ)/MR-J4-100_4(-RJ)
MR-J4-200_4(-RJ) to MR-J4-700_4(-RJ)
MR-J4-11K_4(-RJ)
MR-J4-15K_4(-RJ)
MR-J4-22K_4(-RJ)
MR-J4-DU30K_4 to MR-J4-DU55K_4
6.4.2 Connection example
6.4.3 Dimensions
TF3005C-TX/TF3020C-TX/TF3030C-TX
Length 8
3-M4
6-R3.25
IN
Model
TF3005C-TX
TF3020C-TX
TF3030C-TX
TF3040C-TX
TF3060C-TX
TF3150C-TX
MCCB
Power supply
M4
M4
100±1
100±1
290±2
308±5
332±5
Recommended filter (Soshin Electric)
Rated voltage
Rated current [A]
[V AC]
5
20
30
500
40
60
150
500
EMC filter
1
4
2
5
3
6
E
3-M4
9 - 35
Mass [kg]
Leakage current
[mA]
6
5.5
7.5
12.5
5.5
31
Servo amplifier
MC
L1
L2
L3
L11
L21
[Unit: mm]
M4
(67.5)±3
150±2
(160)
170±5