[Appendix 1] Summary of MR-J4_B_-RJ020 + MR-J4-T20
No.
Symbol
61
NH2
Machine resonance suppression filter 2
Select the machine resonance suppression filter. (Refer to section 7.1.1 of "MELSERVO-J4
series MR-J4-_B_-RJ020 MR-J4-T20 Servo Amplifier Instruction Manual".)
Set "00" when the active vibration suppression control is set as "Enabled" (parameter [Pr. 25]:
_1 _ _).
Setting
digit
_ _ x x
_ x _ _
x _ _ _
Setting value
Name and function
Notch frequency selection
Refer to table 5.6 for the setting value.
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
For manufacturer setting
Table 5.6 Notch frequency selection
Frequency [Hz]
00
Disabled
01
4500
02
2250
03
1500
04
1125
05
900
06
750
07
642.9
08
562.5
09
500
0A
450
0B
409.1
0C
375
0D
346.2
0E
321.4
0F
300
Appendix 1-28
Explanation
Setting value
Frequency [Hz]
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Initial
value
[unit]
0000
Initial
value
00h
0h
0h
281.3
264.7
250
236.8
225
214.3
204.5
195.7
187.5
180
173.1
166.7
160.1
155.2
150
145.2
Setting
range
0000h
to
031Fh