Part 7: Common Reference Material
(6) Conversion rules (MR-J2S-_A_ => MR-J4-_A_)
The following table shows the parameter conversion rules from MR-J2S-_A_ to MR-J4-_A_.
Parameters not specified in the following table will be set to their initial values.
MR-J2S-_A_
No.
Name
Control mode and regenerative
0
option selection
1
Function selection 1
MR-J4-_A_
Type
Target
No.
Type
_ _ _ X
PA01
Hex
Hex
XX_ _
PA02
Hex
X_ _ _
PA03
Hex
_ X _ _
PD27
Hex
Hex
_ _ X _
PD24
Hex
_ _ _ X
PD29
Hex
Hex: hexadecimal parameter; Dec: decimal parameter
7 - 51
Conversion rule
Target
_ _ _ X The setting value will be maintained.
00_ _ will be changed to _ _ 00.
01_ _ will be changed to _ _ 01.
02_ _ will be changed to _ _ 02.
03_ _ will be changed to _ _ 03.
04_ _ will be changed to _ _ 04.
05_ _ will be changed to _ _ 05.
06_ _ will be changed to _ _ 06.
08_ _ will be changed to _ _ 08.
_ _ XX
09_ _ will be changed to _ _ 09.
0E_ _ will be changed to _ _ FA.
82_ _ will be changed to _ _ 82.
83_ _ will be changed to _ _ 83.
84_ _ will be changed to _ _84.
85_ _ will be changed to _ _85.
87_ _ will be changed to _ _81.
Otherwise, _ _ 00 will be set.
0_ _ _ will be changed to _ _ _ 0.
_ _ _ X
1_ _ _ will be changed to _ _ _ 1.
Otherwise, _ _ _0 will be set.
_0_ _ will be changed to _ _03.
_1_ _ will be changed to _ _06.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
_ _ XX
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
_ _0_ will be changed to _ _0C. (ZSP)
_ _1_ will be changed to _ _05. (MBR)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
_ _ XX
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
_ _ _ 1 will be changed to _ _ _ 2.
_ _ _ 2 will be changed to _ _ _ 4.
_ _ _ X
_ _ _ 3 will be changed to _ _ _ 4.
Otherwise, the setting value will be maintained.