Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 532

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

[Appendix 1] Summary of MR-J4_B_-RJ020 + MR-J4-T20
(2) Double-click the setting field "1 to 75" under special parameters "Parameter No." and display the "Servo
special parameter setting" dialog.
(3) Change the parameter setting value.
After changing the setting value of the applicable parameter, click "OK" so that the setting value is
reflected.
Examples of changes of parameter setting values are shown below.
(a) Change of [Pr. 2 regenerative resistor] (hexadecimal parameter)
To change the setting value to "0020", enter "0020" as it is.
(b) Change of [Pr. 12 load inertia moment ratio relative to the servo motor (load inertia ratio) (decimal
parameter)
To change the setting value to "7.0", enter "0046" which is the value resulted from converting "70" to
the hexadecimal number.
(c) Change of [Pr. 39 Electronic dynamic brake operating time] (decimal parameter)
To change the setting value to "10000", enter "2710" which is the value resulted from converting
"10000" to the hexadecimal number.
Appendix 1-69
Double-click
Click

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all

Table of Contents