Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_

3. PARAMETERS

3.1 Comparison of Parameters

Note
(1) Converter unit
(a) Parameter comparison list
MR-HP30K,MR-HP55KA4
No.
Abbreviation
Parameter name
0
*STY
Control mode and regenerative
option selection
4
*DMD
Status display selection
5
*ACL
Alarm history clear
(b) Comparison of parameter details
MR-HP30K,MR-HP55KA4
No.
Name and function
0
Control mode and regenerative option selection
Used to select a control mode and a regenerative option.
0
0
0
0
Selection of regenerative option
0: Not used
1: MR-RB136-4
2: MR-RB138-4(3 units)
3: MR-RB139
4: MR-RB137(3 units)
Setting values "1" and "2" are only for MR-
HP55KA4, while "3" and "4" are only for MR-
HP30KA. Incorrect setting will cause a
parameter error (AL.37).
Never perform extreme adjustments and changes to the parameters, otherwise
the operation may become unstable.
If fixed values are written in the digits of a parameter, do not change these values.
Do not change parameters for manufacturer setting.
Do not enter any setting value other than those specified for each parameter.
POINT
For the parameter converter function, refer to "Part 7: Common Reference
Material".
To enable a parameter whose abbreviation is preceded by *, turn the power
OFF and then ON after setting the parameter.
For details about parameter settings for replacement, refer to the MR-J4-
_A_/MR-J4-_B_ Servo Amplifier Instruction Manual.
With the drive unit, the deceleration to a stop function is enabled in the factory
setting. To disable the deceleration to a stop function, set [Pr. PA04] to "0 _ _ _".
POINT
Manufacturer setting parameters are not described here.
Customer
Initial
setting
value
value
0000h
0000h
0000h
Only for MR-HP55KA4
Only for MR-HP30KA
No.
Abbreviation
PA01
*REG
Regenerative options
PA02
*MCC
Magnetic contactor drive output
selection
PA08
*DMD
Status display selection
PA15
AOP3
Function selection A-3
PA09
*BPS
Alarm history clear
PA12
*DIF
Input filter setting
PA17
*AOP5
Function selection A-5
PA18
CVAT
Voltage sag detection time for
SEMI-F47
Initial
No.
value
PA01
Regenerative options
0000h
Select a regenerative option.
Set correctly otherwise [AL. 37 Parameter error] will
occur.
0
0
0
0
5 - 25
MR-CR55K,MR-CR55K4
Parameter name
MR-CR55K,MR-CR55K4
Name and function
Regenerative option selection
00: Do not use regenerative options
When using a brake unit FR-BU2-(H), select
this value.
01: MR-RB139
02: MR-RB137 (3 units)
13: MR-RB137-4
14: MR-RB13V-4 (3 units)
Customer
Initial
setting
value
value
0000h
0001h
0000h
0000h
0000h
0002h
0001h
200
Initial
value
0000h