Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 330

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 7: Common Reference Material
MR-J2S-_B_
No.
Name
Machine resonance suppression
filter 1
18
(Notch filter)
19
Feed forward gain
20
In-position range
Electromagnetic brake
21
sequence output
MR-J4-_B_
Type
Target
No.
Type
_ _ XX
PB01
Hex
Hex
_ _ XX
PB13
Dec
_ X_ _
PB14
Hex
Dec
-
PB04
Dec
Dec
-
PA10
Dec
Dec
-
PC02
Dec
Hex: hexadecimal parameter; Dec: decimal parameter
7 - 91
Conversion rules
Target
_ _ 00 will be changed to _ _ _ 0.
_ _ _ X
Otherwise, _ _ _ 2 will be set.
_ _ 00 will be changed to 4500.
_ _ 01 will be changed to 4500.
_ _ 02 will be changed to 2250.
_ _ 03 will be changed to 1500.
_ _ 04 will be changed to 1125.
_ _ 05 will be changed to 900.
_ _ 06 will be changed to 750.
_ _ 07 will be changed to 643.
_ _ 08 will be changed to 563.
_ _ 09 will be changed to 500.
_ _ 0A will be changed to 450.
_ _ 0B will be changed to 409.
_ _ 0C will be changed to 375.
_ _ 0D will be changed to 346.
_ _ 0E will be changed to 321.
_ _ 0F will be changed to 300.
-
_ _ 10 will be changed to 281.
_ _ 11 will be changed to 265.
_ _ 12 will be changed to 250.
_ _ 13 will be changed to 237.
_ _ 14 will be changed to 225.
_ _ 15 will be changed to 214.
_ _ 16 will be changed to 205.
_ _ 17 will be changed to 196.
_ _ 18 will be changed to 188.
_ _ 19 will be changed to 180.
_ _ 1A will be changed to 173.
_ _ 1B will be changed to 167.
_ _ 1C will be changed to 160.
_ _ 1D will be changed to 155.
_ _ 1E will be changed to 150.
_ _ 1F will be changed to 145.
_ _ X_
The setting value will be maintained.
-
The setting value will be maintained.
When the setting value of No. 6 is 0, the setting
value of No. 20 will be multiplied by 16.
When the setting value of No. 6 is 1, the setting
value of No. 20 will be multiplied by 32.
When the setting value of No. 6 is 6, the setting
value of No. 20 will be multiplied by 8.
When the setting value of No. 6 is 7 or 255, the
-
setting value of No. 20 will be doubled.
When the above value is 4095 or smaller, the
value will be multiplied by 16.
When the above value is 4096 or larger, 65535
will be set.
To use the HC/HA series servo motors without
being replaced, refer to (2) in Section 2.4.3.
-
The setting value will be maintained.