Part 7: Common Reference Material
MR-J2S-_CP_
No.
Name
79
For manufacturer setting
80
For manufacturer setting
81
For manufacturer setting
MR-J4-_A_-RJ
Type
Target
No.
Type
Hex
_ _ XX
PD22
Hex
_ _ XX
PD12
Hex
Hex
XX _ _
PD06
Hex
_ _ XX
PD08
Hex
Hex
XX _ _
PD10
Hex
Hex: hexadecimal parameter; Dec: decimal parameter
7 - 71
Conversion rule
Target
The setting value will be converted as shown in
Table 1 (as input).
However, a setting value other than those in
Table 1 will be converted to 2B _ _.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
XX _ _
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
However, a setting value other than those in
Table 1 will be converted to 38 _ _.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
XX _ _
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
The setting value will be converted as shown in
Table 1 (as input).
However, a setting value other than those in
Table 1 will be converted to 20 _ _.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
XX _ _
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
The setting value will be converted as shown in
Table 1 (as input).
However, a setting value other than those in
Table 1 will be converted to 07 _ _.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
XX _ _
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
The setting value will be converted as shown in
Table 1 (as input).
However, a setting value other than those in
Table 1 will be converted to 08 _ _.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
XX _ _
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.