Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
MR-J2S-_CP_ or MR-J2S-_CL_
No.
Name and function
18
Status display selection
This is used to select a status display shown at power-
on.
Servo amplifier status display at power-on
00: Current position (initial value)
01: Command position
02: Command remaining distance
03: Point table No.
04: Cumulative Feedback Pulses
05: Servo motor speed
06: Droop pulses
07: Override voltage
08: Torque limit voltage
09: Regenerative load ratio
0A: Effective load ratio
0B: Peak load ratio
0C: Instantaneous torque
0D: Within one-revolution position at low
0E: Within one-revolution position at high
0F: ABS counter
10: Motor inertia ratio
11: Bus voltage
Status display at power-on in MR-DP60
status
00: Current position (initial value)
01: Command position
02: Command remaining distance
03: Point table No.
04: Cumulative Feedback Pulses
05: Servo motor speed
06: Droop pulses
07: Override voltage
08: Torque limit voltage
09: Regenerative load ratio
0A: Effective load ratio
0B: Peak load ratio
0C: Instantaneous torque
0D: Within one-revolution position
0E: ABS counter
0F: Motor inertia ratio
10: Bus voltage
Initial value
No.
CP
CL
0000h
PC36
Status display selection
Status display selection at power-on
Refer to the comparison table below for the setting
method.
Status display selection comparison table
Selection of servo amplifier status display at
power-on
Status display selection comparison table
Selection of servo amplifier status display at power-on
MR-J2S-_CP_
No.18
_ _ 0 0
_ _ 0 1
_ _ 0 2
_ _ 0 3
_ _ 0 4
_ _ 0 5
_ _ 0 6
_ _ 0 7
_ _ 0 8
_ _ 0 9
_ _ 0 A
_ _ 0 B
_ _ 0 C
_ _ 0 D
_ _ 0 E
_ _ 0 F
_ _ 1 0
_ _ 1 1
4 - 25
MR-J4-_A_-RJ
Name and function
MR-J4-_A_-RJ
Display definition
PC36
0 _ 2 1
Current position
0 _ 2 2
Command position
0 _ 2 3
Command remaining distance
0 _ 2 4
Point table No.
0 _ 0 0
Cumulative feedback pulses
0 _ 0 1
Servo motor speed
0 _ 0 2
Droop pulses
0 _ 2 6
Override voltage
0 _ 0 6
Analog torque limit voltage
0 _ 0 7
Regenerative load ratio
0 _ 0 8
Effective load ratio
0 _ 0 9
Peak load ratio
0 _ 0 A
Instantaneous torque
0 _ 0 B
Within one-revolution position
(1-pulse unit)
0 _ 0 C
Within one-revolution position
(1000-pulse unit)
ABS counter
0 _ 0 D
0 _ 0 E
Load to motor inertia ratio
0 _ 0 F
Bus voltage
Initial
value
0000h