NEC Xen Topaz Features And Specifications Manual page 350

Hide thumbs Also See for Xen Topaz:
Table of Contents

Advertisement

NEC Business Solutions Ltd
Chapter 4 - 342
40-03-02: Message recording setup - Guidance message in case recording
not allowed
When the answering service cannot record messages, sets whether to
transmit the answering message of the mailbox or the fixed guidance (0
= fixed guidance, 1 = Answering message of mailbox).
40-03-03: Message recording setup - Automatic answering transmission for
busy line
Defines whether to automatically play the answering message for a busy
extension (0 = disable, 1 = enable).
40-04-01: Live recording setup - operation mode when mailbox is not defined
Defines whether to record conversation in temporary box or callback
extension to enter mailbox if mailbox is not defined in 14-09-01 or 15-12-
01 (0 = temporary box, 1 = callback operation).
40-04-02: Live recording setup - Temporary box number
Sets the box number to keep the unknown destination messages, 0 to
300 as defined in 40-02.
40-04-03: Live recording setup - Live recording display
Enables or disables the system's ability to display the recording feature
active (0 = disabled, 1 = enabled).
40-05-01: Call information setup (for notification) - Maximum number of out-
going calls
Sets the maximum number of calls the voice mail can make simulta-
neously from 0 to 16, if set to 0 voice mail will not notify.
40-05-02: Call information setup (for notification) - Trunk route number
Sets the trunk route number to use for outgoing calls from 0 to 100, if set
to 0 voice mail will not notify.
40-05-03: Call information setup (for notification) - ISDN calling number set-
ting
Sets the caller number when an outgoing call is made using an ISDN
line. Maximum 16 digits 0-9, * and #.
40-05-04: Call information setup (for notification) - Calling interval (exten-
sion)
Sets the calling interval when calling an extension, 1 to 30 minutes.
40-05-05: Call information setup (for notification) - Calling interval (trunk)
Sets the calling interval when calling a trunk line, 1 to 30 minutes.
40-05-06: Call information setup (for notification) - Maximum calling count
(extension)
Sets the maximum number of times to call an extension, 1 to 100.
40-05-07: Call information setup (for notification) - Maximum calling count
(trunk)
Sets the maximum number of times to call an extension, 1 to 100.
40-06-01: Trunk answering Service Setting - Operation mode
Defines on a per trunk per day/night mode whether to enable General
Auto Attendant = answering and recording, 1 = not used.
XEN Topaz
Features

Advertisement

Table of Contents
loading

Table of Contents