(Refer to "2.3 (II). Tool Offset
(M system)" for M system.
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
3) Deleting a group registration
The group being displayed and its data can be deleted by pressing
4) Registering tools
Set the tools in order from the first tool to be used. If multiple compensation Nos. are used
with one tool, set the tool No. and respective compensation Nos. for each compensation
No.
• Tool No.
: Set the tool No. (1 to 999999: differs according to the specifications)
• Compensation No. : Set the compensation No. (1 to 80: differs according to the
• USED
: When the designated tool is other than a not-used tool, the initial
• ST
: Designate whether the tool is a tool skip tool or not. (Can be omitted.)
(Example) Setting to use multiple compensation Nos. with one tool.
#
Tool No.
1
2
3
(Note)
Tool life management is carried out in group units with this function. Thus, if a tool
is set in a different group, the life will be managed according to the respective
group, and that tool cannot be managed correctly.
5) Deleting a tool registration
Set 0 in the tool No. of the # No. to be deleted. All data of that # No. will be deleted, and the
subsequent # Nos. and data will all move up a line.
search engine
2.3 (I). Tool Offset (L system)
specifications)
incrementation value can be adjusted by setting the USED data.
If no data is set, this value becomes 0. (Can be omitted.)
If the data is not set, or if 0 to 2 is set, the data will be automatically
set according to the relation with the USED data and LIFE data.
0: Not used tool
2: Normal life-reached tool
Compensation No.
520000
11
520000
12
520000
13
I - 69
CAN
SHIFT
+
1: Current tool (tool being used)
3: Tool skip tool
..... Equivalent to a T52000011 command.
..... Equivalent to a T52000012 command.
..... Equivalent to a T52000013 command.
INPUT
+
.
C.B