T02 FEED HOLD
Error No.
0201
0202
0203
0204
0205
0206
0215
Downloaded from
ManualsNet.com
Details
H/W STRK END (H/W stroke end axis)
An axis is at the stroke end.
S/W STRK END (S/W stroke end axis)
An axis is at the stored stroke limit.
RSET SGNL ON (Reset signal on)
The reset signal has been input.
AUTO OP STOP (Automatic operation
stop)
The FEED HOLD switch is "ON".
AUTO MD CHING (Automatic mode
change)
The operation mode changed to another
mode during automatic operation.
Acceleration and deceleration time
constants too large
The acceleration and deceleration time
constants are too large. (This problem
occurs at the same time as system
alarm Z59.)
Absolute position detection alarm stop
An absolute position detection alarm
occurred.
search engine
7. List of Alarms
7.2 Stop Codes
The feed hold state been entered due to a condition in the
automatic operation.
• Manually move the axis away from the
stroke end limit switch.
• The machining program must be
corrected.
• Manually move the axis.
• The machining program must be
corrected.
• The program execution position has
returned to the start of the program.
Execute automatic operation from the
start of the machining program.
• Resume automatic operation by
pressing the "CYCLE START" switch.
• Return to the original automatic
operation mode‚ and resume
automatic operation by pressing the
"CYCLE START" switch.
• Increase the set value of the "#1206
G1bF" parameter.
• Decrease the set value of the "#1207
G1btL" parameter.
• Lower the cutting speed.
• Reset the absolute position detection
alarm.