(Note 1) If the NC memory's machining program number is not designated when inputting or
(Note 2) If a file with the same No. as a program existing in the NC memory is input, the error
(Note 3) The first O No. line in the machining program is ignored.
(Note 4) • When machining program is designated with "#10 DATA":
(Note 5) Files batch input or compared with "*" or "+" are limited to files having a name of eight
(Note 6) If the program to be overwritten is running, the error "E21 PROGRAM RUNNING" will

2.6.6.4 Output (#( 3))

• Machining programs in the NC memory are output as flash ATA card files.
• The name of the file to be output is designated with eight or less alphanumeric characters.
• Machining programs can be output as files with extensions. Batch designated output is also possible.
• If the flash ATA card capacity is filled during the output, the data output up to that point will be
registered as a file, and then the error "E113 MEMORY OVER" will occur.
• When outputting tool data, parameter, history data, maintenance data or fixed cycle programs, a
unique extension will be automatically added to the designated file name.
• If reset is executed during the output, the output data up to that point will be valid.
(1) Example of output setting
Example 1
Example 2
Example 3
Example 4
(2) Precautions
(Note 1) If the file name is not designated when outputting, the same name as the machining
(Note 2) The error "E111 FILE DUPLICATE" will occur if a machining program with the same No.
(Note 3) When outputting the machining programs with an extension, if an extension unique to
(Note 4) Do not designate extensions for tool data or parameter data, etc., to which unique
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
comparing, the same No. as the file name will be used.
Note that this setting is valid only when the file name consists of only the numbers of
eight or less digits.
An error will occur if the file name contains alphabetic characters or has an extension.
"E65 PROG. No. DUPLI" will occur.
Note that during batch input, a message confirming whether to overwrite will appear.
If "PROG" is designated for the file name, the file name "PROG" (no extension) will be
read out.
• If tool data or parameter data, etc., is designated with "#10 DATA":
If "PROG" is designated for the file name, the file with a unique extension
automatically assigned, such as "PROG.OFS" (tool data) or "PROG.PRM" (parameter
data) will be read out.
digits or lower numbers. Even when there is no extension, if the file name contains
alphabetic characters, it cannot be batch input or compared with the above operations.
(It will be ignored.)
occur, and the batch input will end.
Example of conditions
Output machining program No. "200" as file
name "100".
Output machining program No. "20" as file
name "FILE.PRG".
Batch output all machining programs in the
NC memory as file "ALL.PRG".
Batch output all machining programs in the
NC memory as file "ALPRG.PRG".
program will be used.
as a file name existing in the flash ATA card is designated.
Note that during batch output, a message confirming whether to overwrite will appear.
the data (.ofs, .prm, etc.) is used, the error "E01 SETTING ERROR" will occur.
extension are automatically assigned. If an extension is assigned, and that designated
extension differs from the automatically assigned extension, the error "E01 SETTING
ERROR" will occur.
search engine
2.6 Data In/Out
# ( 3) (
# ( 3) (
# ( 3) (
# ( 3) (
I - 175
Setting
200) (
100)
20) (
FILE.PRG)
ALL) (
)
ALL) (
ALPRG.PRG)