2. Startup and Adjustment Procedures

2.1 Checking the Connection

Refer to the Connection Manual and check the connection of each unit and communication terminal,
etc.
Pay special attention to the position of the input power supply and connectors, etc. It is recommended
to leave the servo motor and spindle motor power cables disconnected until setting of the parameters,
etc., is completed.

2.2 Setting the Various Switches

(1) Control unit setting switch (CS1)
A rotary switch: CS1 (left side) is located at the top front of the control unit.
Normally, the rotary switch is set to "0". Set it as shown below as necessary.
(2) Control unit setting switch (CS2)
A rotary switch: CS2 (right side) is located at the top front of the control unit.
This switch is used when two or more C6/C64 control units are to be connected to a single
communication terminal. (Use it along with CS1 and SW1 switches.)
Downloaded from
ManualsNet.com
2. Startup and Adjustment Procedures
CAUTION
Always ground the signal cable to ensure stable operation of the system. Use one-point
grounding to provide the same potential at the control unit body, distribution panel and
machine.
Switch
0
Normal operation mode
1
PLC program stops
2
Not used
3
Maintenance mode used by manufacturer
4
Not used
5
Maintenance mode used by manufacturer
6
Not used
7
Memory all erase
8 to F
Maintenance mode used by manufacturer
Switch
0
Normal operation mode
1
Designation of the station No. "n0" for multiple C6/C64 controllers.
2
Designation of the station No. "n1" for multiple C6/C64 controllers.
:
:
F
Designation of the station No. "n15" for multiple C6/C64 controllers.
search engine
2.1 Checking the Connection
Operation
Operation
III - 4
Application
Normal operation
PLC development work
Do not use.
Do not use.
Do not use.
Do not use.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents