Daily Maintenance And Periodic Inspection; Daily Inspection; Checking The External View; Checking The Inside Of The Control Panel - Mitsubishi Electric MELDAS C6 Instruction Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

7. Daily Maintenance and Periodic Inspection

7.1 Daily Inspection

7.1.1 Checking the External View

(1) Machine oil (cutting oil, lubrication oil) have been scattered onto the servomotor, detector, or
control unit, or is leaking.
(2) Damage is found on the cables of the movable blocks, or the cables are twisted.
(3) Filter clogging
(4) A door of the control panel is not open.
(5) Ambient vibration
(6) The unit is located in a dusty location.
(7) Something that causes high frequency is placed near the NC unit.

7.1.2 Checking the Inside of the Control Panel

(1) Cable connectors are loosened.
(2) Installing screws are loosened.
(3) Attachment amplifier screws are loosened.
(4) The cooling fan operates abnormally.
(5) Cable damage
(6) PCB have been inserted abnormally.

7.2 Maintenance Tool

(1) Measuring instruments
The following measuring instruments are used to confirm that the voltage is being supplied
correctly to the NC unit, to confirm that the wiring to the NC unit is correct, and to carry out simple
troubleshooting.
Tester
AC voltmeter
DC voltmeter
Synchroscope
(Note 1) Currently, a high precision digital multi-meter is commonly used as a tester. This digital
(2) Tools
Downloaded from
ManualsNet.com
7. Daily Maintenance and Periodic Inspection
Tool
Condition
Measure the AC power voltage.
The tolerable error is ±2%
or less.
Max. scale 30V.
The tolerable error is ±2%
or less.
multi-meter can be used as both an AC voltmeter and a DC voltmeter.
Screwdriver (large, medium, small)
Radio pliers
search engine
7.1 Daily Inspection
To check that the wiring to the NC unit is correct
before turning the power ON.
To measure the AC power voltage being
supplied to the external 24VDC power supply
unit.
To measure the DC power voltage.
External power supply 24V (control section,
machine input/output interface)
Battery voltage
HR851 SA output
General measurement and simple
troubleshooting
III - 44