Alarm No.
9E
9F
A6
A8
A9
E0
E1
E2
E3
E4
E6
E7
E8
E9
EA
EB
Downloaded from
ManualsNet.com
7.3 Servo ⋅ Spindle Alarms
Name
Absolute position
An error was detected in the revolution counter of the absolute
detector:
position detector. The absolute position data cannot be
Revolution counter
compensated.
error
Battery voltage
The battery voltage that is supplied to the absolute position detector
drop
dropped. The absolute position data is retained.
Fan stop warning
A cooling fan built in the drive unit stopped.
Turret indexing
The designated position shift amount of turret indexing is outside the
warning
setting range.
Orientation
As an orientation feedback error occurred, the retrial has been
feedback warning
conducted.
Over regeneration
Over-regeneration detection level exceeded 80%.
warning
Overload warning
Overload detection level exceeded 80%.
Continuous
The motor was continuously rotated at a speed exceeding the rated
high-speed
speed.
revolution warning
Absolute position
Deviation between the absolute and relative position data was
counter warning
detected.
Set parameter
A parameter setting was outside the setting range.
warning
Control axis
Control axis detachment was commanded.
detachment
warning
In NC emergency
Emergency stop was input from the CNC.
stop state
Excessive
Regeneration that are beyond the power supply limitation has
supplementary
frequently occurred.
regeneration
frequency
Instantaneous
The power was momentarily interrupted.
power interruption
warning
In external
External emergency stop signal was input.
emergency stop
state
Over regeneration
Over-regeneration detection level exceeded 80%.
warning