Error No.
P275
P276
P277
P280
P281
P282
P283
P290
P291
P292
P293
P294
P295
P296
Downloaded from
ManualsNet.com
Details
MACRO ARG. EX.
The number of macro call argument type
II sets has exceeded the limit.
CALL CANCEL
A G67 command was issued though it
was not during the G66 command modal.
MACRO ALM MESG
An alarm command has been issued in
#3000.
EXC. [ ‚ ]
The number of parentheses [ ‚ ] which
can be commanded in a single block has
exceeded five.
[ ‚ ] ILLEGAL
The number of "[" and "]" parentheses
commanded in a single block does not
match.
CALC. IMPOSS.
The arithmetic formula is incorrect.
DIVIDE BY ZERO
The denominator of the division is zero.
IF SNT. ERROR
There is an error in the IF conditional
GOTO
statement.
WHILE SNT. ERR
There is an error in the WHILE
conditional DO -END
SETVN SNT. ERR
There is an error in the SETVN
statement when the variable name
setting was made.
DO-END EXCESS
The number of
's for DO-END
WHILE conditional DO
statement has exceed 27.
DO-END MMC.
The DO's and END's are not paired off
properly.
WHILE/GOTO TPE
There is a WHILE or GOTO statement on
the tape during tape operation.
NO ADR (MACRO)
A required address has not been specified
in the user macro.
search engine
7. List of Alarms
7.10 Program Error
• Review the program.
• Review the program.
• The G67 command is the call cancel
command and so the G66 command must
be designated first before it is issued.
• Refer to the operator messages on the
DIAG screen.
• Refer to the instruction manual issued by
the machine manufacturer.
• Review the program and correct it so the
number of "[" or "]" does not exceed five.
• Review the program and correct it so that
"[" and "]" parentheses are paired up
properly.
• Review the program and correct the
formula.
• Review the program and correct it so that
the denominator for division in the formula
is not zero.
• Review the program.
• Review the program.
statement.
• Review the program.
• The number of characters in the variable
name of the SETVN statement must be 7 or
less.
• Review the program and correct it so that
the number of 's in the DO – END
in the
statement does not exceed 27.
– END
• Review the program and correct it so that
the DO's and END's are paired off properly.
• During tape operation‚ a program which
includes a WHILE or GOTO statement
cannot be executed and so the memory
operation mode is established instead.
• Review the program.