Alarm
information
0033
0046
0050
0051
0052
(4) S52 AUX SERVO WRN
Alarm
information
0092
00E0
00E1
Downloaded from
ManualsNet.com
7.11 Auxiliary Axis Alarms
Details
Overvoltage
The voltage of the converter in the
servo drive unit was 400V or
more.
Motor overheating An operation state causing the
motor to overheat continued.
Overload 1
The servo drive unit or
servomotor overload protection
function activated.
Overload 2
The max. output current flowed
for several seconds due to a
machine collision or overload.
Excessive error
A position deflection exceeding
the excessive error detection
setting value occurred.
Details
Battery voltage
The absolute position detection
drop
battery voltage dropped.
Over-regeneration
The regeneration power may
warning
have exceeded the tolerable
range of the built-in regenerative
resistor or external regenerative
option.
Overload warning
The overload alarm 1 could occur. • Refer to the items for S03 0050.
search engine
7. List of Alarms
IV - 85
Remedy
• Wire correctly.
• Replace the servo drive unit.
• For the internal regenerative
resistor, replace the drive unit.
• For the external regenerative
option, replace the regenerative
option.
• Reduce the motor load.
• Review the operation pattern.
• Reduce the motor load.
• Review the operation pattern.
• Change to a motor or drive unit
with large output.
• Change the setting of the
automatic tuning response
characteristics.
• Correct the connection.
• Replace the servomotor.
• Review the operation pattern.
• Change the setting of the
automatic tuning response
characteristics.
• Correct the connection.
• Replace the servomotor.
• Increase the acceleration/
deceleration time constant.
• Increase the torque limit value.
• Review the power facility capacity.
• Review the operation pattern.
• Replace the servomotor.
• Connect correctly.
• Repair or replace the cable.
Remedy
• Mount a battery.
• Replace the battery and initialize
the absolute position.
• Lower the positioning frequency.
• Change the regenerative option
to a larger one.
• Lower the load.