Mitsubishi Electric MELDAS C6 Instruction Manual page 493

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Error No.
P223
P224
P230
P231
P232
P241
P242
P243
P260
P270
P271
P272
P273
Downloaded from
ManualsNet.com
Details
G12 G13 R ERR
The radius value specified with a G12 or
G13 command is below the
compensation amount.
NO G12‚ G13 SPC
There are no circular cutting specifica-
tions.
NESTING OVER
A subprogram has been called 8 or more
times in succession from the subprogram.
NO N-NUMBER
At subprogram call time‚ the sequence
number set at return from the subprogram
or specified by GOTO‚ was not set.
NO PROGRAM No.
The subprogram has not been set when
the subprogram is called.
NO VARl NUMBER
The variable number commanded is
higher than the numbers in the specifica-
tions.
EQL. SYM. MSSG.
The "=" sign has not been commanded
when a variable is defined.
VARIABLE ERR.
An invalid variable has been specified in
the left or right side of an operation
expression.
NO COOD-RT SPC
Even though there were no coordinate
rotation specifications, a coordinate
rotation command was issued.
NO MACRO SPEC
A macro specification was commanded
though there are no such command
specifications.
NO MACRO INT.
A macro interrupt command has been
issued though it is not included in the
specifications.
MACRO ILL.
A statement and a macro statement exist
together in the same block.
MACRO OVERCALL
The frequency of the macro call has
exceeded the limit.
search engine
7. List of Alarms
7.10 Program Error
• Review the program.
• Check the specifications.
• Check the number of subprogram calls and
correct the program so that it does not
exceed 8 times.
• Specify the sequence numbers in the call
block of the subprogram.
• Enter the subprogram.
• Check the specifications.
• Check the program variable number.
• Designate the "=" sign in the variable
definition of the program.
• Correct the program.
• Check the specifications.
• Check the specifications.
• Check the specifications.
• Review the program and place the
executable statement and macro statement
in separate blocks.
• Review the program and correct it so that
the macro calls do not exceed the limit
imposed by the specification.
IV - 77
Remedy