Error No.
000B
000C
000E
000F
0010
0011
0013
Downloaded from
ManualsNet.com
Details
The object is already in the mode or state
requested by the service.
The object cannot execute the requested
service in the current mode or state.
A request to change a change prohibited
attribute was received.
The enable/special rights check failed.
The requested service cannot be executed
in the current device state.
The slave did not respond.
Sufficient data to execute the designated
operation has not been provided.
search engine
7. List of Alarms
7.8 Communication Error
IV - 57
Remedy
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Check the current status using attribute
read.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Check the current status using attribute
read.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Generally check the state of the
network and slave, and check that the
slave is not down, and that the
terminator is not disconnected, etc.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
When executing attribute write, check
that the designated data is not
insufficient, and that the data length is
correct.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.