(Refer to "2.3 (II). Tool Offset
(M system)" for M system.
(3) Measurement value input method
Tool length = Machine value - Measurement base point (tlml) - Measurement value
The expression above is used for automatic calculation in the measurement value input method.
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
Set the type selection to the measurement value input method. (Set "#1102 tlm" to 1).
To carry out the measurement value input method, a workpiece for measuring is required. To
measure the workpiece, set the measurement base point in parameter "#2015 tlml–" beforehand.
Measurement
base point
Measurement
base point
Z-axis measurement
Z-axis + tlml
search engine
2.3 (I). Tool Offset (L system)
X-axis measurement
value
X-axis + tlml
Tool length
base point
I - 54