(2) Messages displayed on the BACKUP screen
The following table shows the messages displayed on the BACKUP screen and their details.
CONTINUE Y/N
BACKUP EXECUTION The auxiliary axis parameters are being backed up in the SRAM.
BACKUP COMPLETE
AUX. WRITING EXEC. The auxiliary axis parameters in the SRAM are being written into the
WRITE COMPLETE
ABS POS RESTORED The absolute position in the SRAM has been restored to the MR-J2-CT.
(3) Supplementary Items
The following shows the process when the No. of axes set in the set up parameters differs from the
No. of MR-J2-CT axes connected.
MR-J2-CT parameter input
MR-J2-CT parameter output
The following shows the process when there are more input data axis Nos. than there are axes set in
the setup parameters.
MR-J2-CT parameter input
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
Message
Determine whether to execute the operation by selecting either "Y" or "N".
The SRAM backup of the auxiliary axis parameters is finished.
MR-J2-CT.
The writing of the auxiliary axis parameters in the SRAM to the MR-J2-CT
is finished.
search engine
2.7 Diagnosis
No. of axes set No. of axes connected, or the
No. of axes set = 0.
MR-J2-CT parameter input not carried out.
MR-J2-CT parameter output not carried out.
Input data axis No. > No. of axes set
Input data exceeding the No. of set axes is not input.
I - 215