Link Startup Mode Selection (N10 ) - Mitsubishi Electric FR-S500E Instruction Manual

Frequency inverter
Table of Contents

Advertisement

Communication parameters
n8 (Pr. 338) "operation
Operation
command source"
location
n9 (Pr. 339) "speed
selection
command source"
RH, RM,
Remote setting
(RH, RM, RL)
RL, REX
selection
15-speed selection (REX)
function
MRS
PU operation interlock
selection
(MRS)
function
[Explanation of table]
External
: Operation is valid only from external terminal signal.
Computer
: Operation is valid only from computer.
Combined
: Operation is valid from either of external terminal and computer.
: Operation is invalid from either of external terminal and computer.
CAUTION
When Pr. 79 "operation mode selection" is set to "7" (PU operation interlock
function), only the external terminal is made valid independently of the n8 and
n9 settings because the MRS terminal is shared.
2.15.3 Link startup mode selection (n10
The operation mode at power on and at power restoration after instantaneous
power failure can be selected.
Set "1" in n10 to select the computer link operation mode.
After a link start, parameter write is enabled with a program.
Parameter
Name
Link startup
n10 (340)
mode selection
The parameter number in parentheses is the one for use with the parameter unit (FR-
PU04).
0:
Computer
0:
Computer
Computer External Computer External
External
Factory
Setting
Setting
Range
0
0, 1
Setting is enabled when Pr. 30 = "1"
146
0:
1:
Computer
External
1:
0:
External
Computer
External
External
)
Remarks
1:
External
Remarks
1:
External
Pr. 59 =
"1", "2"
External Pr. 79 = "7"