4 POSITIONING SIGNALS

4. POSITIONING SIGNALS
The internal signals of the Motion CPU and the external signals to the Motion CPU
are used as positioning signals.
(1) Internal signals
(2) External signals
Sensor, solenoid, etc.
(DI/O)
The following five devices of the Motion CPU are used as the internal signals of
the Motion CPU.
• Internal relay (M) .............................. M2000 to M3839 (1840 points)
• Special relay (SP.M) ........................ M9073 to M9079 (7 points)
• Data register (D) .............................. D0 to D1631 (1632 points)
• Motion register (#) ........................... #8000 to #8191 (192 points)
• Special register (SP.D) .................... D9112 and D9180 to D9201 (23 points)
The external input signals to the Motion CPU are shown below.
• Upper/lower limit switch input .......... The upper/lower limit of the positioning
• Stop signal ....................................... Stop signal for speed control
• Proximity dog signal ........................ ON/OFF signal from the proximity dog
• Manual pulse generator input .......... Signal from the manual pulse generator
Configuration between modules
PLC CPU
1)
Device memory
PLC control
processor
Shared CPU
memory
PLC intelligent function
module (A/D, D/A, etc.)
Fig.4.1 Flow of the internal signals/external signals
4 - 1
M4000 to M4719 (720 points)
D1650 to D1679 (30 points)
range is controlled.
Motion CPU
2)
Device memory
Motion control
processor
Shared CPU
memory
PLC bus
Motion control dedicated I/F
(DOG signal, manual
pulse generator)
SSCNET
Servo amplifier
M
M
Servomotor
Note) : Device memory data : 1) = 2)