Mitsubishi Electric Q Series Programming Manual page 63

Motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

3 MOTION DEDICATED PLC INSTRUCTION
Moving Backward during Positioning
G-code Instruction
G00
G28 (High-speed home position return)
G30
G53
G02
G03
G01
G32
G25
G28 (Proximity dog, count, data set, dog
cradle, stopper and limit switch combined type
home position return)
JOG operation
(Note) : Minor error (Error code : 301) : Speed change was made during home position return.
[Description]
When a speed change is made to a negative speed by the CHGV instruction, the travel
direction can be changed to the direction opposite to the intended positioning direction.
Operation for each instruction is as follows.
The axis is reversed in travel direction, returns to the positioning start
point at the specified speed, and stops (stands by) there.
The axis is reversed in travel direction, returns to the preceding point at
the specified speed, and stops (waits) there.
Speed change cannot be
made.
Speed change to negative
speed is not made.
Speed is controlled at speed
limit value.
Minor error (Error code : 305) : Preset speed is outside the range of 0 to speed limit value.
Minor error (Error code : 310) : Speed change was made during high-speed oscillation.
(1) When a speed change is made to negative speed, speed is controlled as listed
above according to the G-code in execution.
(2) The backing command speed is the absolute value of the new speed. If it exceeds
the speed limit value, a minor error (Error code : 305) occurs and the speed is
controlled at the speed limit value.
Operation
Minor error (Error code : 310)
Minor error (Error code : 301)
Minor error (Error code : 305)
3 - 28
(Note)
occurs.
(Note)
occurs.
(Note)
occurs.