Mitsubishi Electric Q Series Programming Manual page 164

Motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

4 POSITIONING SIGNALS
Error code
1
S/W falut 1
Operation cycle time over
2
Q bus WDT error
3
4
WDT error
Information processor H/W error
30
Q bus H/W fault
201
Error contents
01 : Q bus error 1
201 to 215
02 : Q bus error 2
04 : Q bus error 4
08 : Q bus error 8
Error code = Total of the error contents + 200
Servo amplifier interface H/W fault
250
Faulty SSCNET
250 to 253
0 : SSCNET 1
1 : SSCENT 2
Error code = Total of the faulty SSCNET No. + 250
300
S/W fault3
8 or more points of CPSTART instruction were used
to start programs in excess of simultaneously
startable program.
301
Number of simultaneous startable programs
(3) Motion CPU WDT error cause (D9184) ................. Monitor device
This register is used as judgement of the error contents in the Motion CPU.
Error cause
No.
14
Operation when error
occurs
All axes stop immediately,
after which operation
cannot be started.
4 - 85
Action to take
• Reset with the reset key.
• If the error reoccurs after resetting,
change the operation cycle into a large
value in the system setting.
• Reset with the reset key.
• If the error reoccurs after resetting, the
relevant module or the relevant slot
(base unit) is probably faulty: replace
the module/base unit.
• Reset with the reset key.
• If the error reoccurs after resetting,
explain the error symptom and get
advice from our sales representative.
• Reset with the reset key.
• If the error reoccurs after resetting, the
relevant module or the relevant slot
(base unit) is probably faulty: replace
the module/base unit.
• Reset with the reset key.
• Reset with the reset key.
• Use 8 or more points of CPSTART
instruction to start programs within the
number of simultaneously startable
programs.

Advertisement