7 AUXILIARY AND APPLIED FUNCTIONS
(5) The setting manual pulse generator 1-pulse input magnification checks the "1-
pulse input magnification setting registers of the manual pulse generator" of the
applicable axis at the turning manual pulse generator enable flag turns off to on.
If the value is outside of range, the manual pulse generator axis setting error
register (D9185 to D9187) and manual pulse generator axis setting error flag
(M9077) are set and a value of "1" is used for the magnification.
(6) Manual pulse generator smoothing magnification setting
A magnification to smooth the turning the manual pulse generator operation off to
on or on to off is set.
Manual pulse generator smoothing
magnification setting register
Manual pulse generator 1 (P1) : D752
Manual pulse generator 2 (P2) : D753
Manual pulse generator 3 (P3) : D754
(a) Operation
Manual pulse generator input
Manual pulse generator 1
enable flag (M2051)
Output speed (V1) = [Number of input pulses/ms]
Travel value (L) = [Travel value per pulse]
(b) When the smoothing magnification is set, the smoothing time constant is as
following formula.
Smoothing time constant (t) = (Smoothing magnification + 1)
REMARK
The smoothing time constant is within the range of 56.8 to 3408[ms].
Setting range
ON
OFF
V
t
t
generator 1-pluse input magnification setting]
[Manual pulse generator 1-pluse input magnification
setting]
7 - 64
0 to 59
V1
t
t
[Manual pulse
[Number of input pulses]
56.8 [ms]