Nortel DMS-100 Series Maintenance Manual page 191

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Example of a MAP response:
Node is ISTb
One or both units inservice trouble
Unit 0
The following inservice troubles exist:
Static data mismatch with CC
Unit 1
The following inservice troubles exist:
Static data mismatch with CC
If
the system displays a card list
P-side links are out of service
static data mismatch with CC
PM load mismatch with inventory
table
data is out of date
none of the above conditions
occur
14
To busy the inactive unit, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
15
To load the inactive unit, type
>LOADPM UNIT unit_no CC DATA
and press the Enter key.
where
unit_no
is the number of the inactive unit
If LOADPM
passes
fails
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-27
minor
(continued)
Do
step 34
step 38
step 17
step 19
step 14
step 28
Do
step 16
step 45
PM SMS